Option 31 - Walk Test [Quick Menu Option 6] - Honeywell GX-Series Installation And Setup Manual

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
Test Options
NOTE: Test frequency of the control panel and all accessories once per year.
Option 31 – Walk Test [Quick Menu Option 6]
31.1 = View
This option allows the user to log on to any keypad to view which zones have been tested and which zones
have still to be tested.
1 = Zones Untested
If this option is selected then the first zone that has not been tested will be displayed. Pressing the A> or
<B keys scrolls through all the untested zones.
2 = Zones Tested
If this option is selected then the user can view those zones already tested.
31.2 = Activate
This option allows a Walk Test to be carried out silently or audibly.
1 = Silent
This option allows the user to do a Walk Test that does not produce any audible sound. It will be
completely silent. The Walk Test offers two methods of testing zones:
1 = Test all Zones
This option initiates a Walk Test that includes all zones that have the omit attribute enabled (refer
to option 52 = PROGRAM ZONES). When selected, the Walk Test starts immediately. The
message NO ENTRIES is displayed if all zones are non-omittable when selecting All Zones. Non-
omittable zones are not included in this test and remain active throughout the test.
2 = Selected Zones
This option allows the user to select any zones, irrespective of function type, for walk testing. As
many zones as necessary may be added to the list before starting the test. On entering this option
the details of the first zone are displayed. Each zone required for test can be selected using the A> or
<B keys or by entering the zone number. Press the # key to toggle the test status of each zone in the
Walk Test: the test status of the zone changes to TEST if it is included in the test and # = TEST if it
is not. When all the required zones have been selected, press the ent key to start the Walk Test.
Press the * key to include all zones in the Selected Zones Walk Test, without having to individually
select the zones. Once all zones are selected, the # key can be used to remove selected zones from the
test.
NOTE: PA, PA Silent, PA Delay, PA Silent Delay and Fire are not included in the test when the * key
is used to include all zones.
31 = Walk Test
1 = View
1 = Zones Untested
2 = Zones Tested
2 = Activate
1 = Silent
2 = Audible
Figure 6-1. Walk Test Menu
1 = Test all Zones
2 = Selected Zones
1 = Test All Zones
2 = Selected Zones
6-18
GX-049-V0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48