the esc key to abort the programming. The address and function of the first zone on the system are
displayed:
Copy Start: Use the A> or <B key to select the first zone in the range to be copied and press the ent
key. The function of this zone will be copied to all subsequent zones in the range;
Copy End: Use the A> key to move to the last zone in the range to be copied.
Press the ent key to copy the zone function to the selected range.
26 = Forced
The Forced parameter enables or disables Menu option 14 = FORCED SET (Forced Bypass). If the
parameter is set to 1 (enabled) the user can force the system to set (arm), automatically omitting (bypassing)
any omittable zones that are open at the time of setting (arming). If the parameter is set to 0 (disabled),
option 14 = FORCED SET (Forced Bypass) is not available to the user; the message Option not
available is displayed. The parameter defaults to 0 (disabled).
NOTE: It is recommended that Final, Entry and Push-Set zones have the omit (bypass) attribute disabled.
27 = CCT Debounce
The cct Debounce parameter determines the response time of the zones (how long they must remain open
before registering as changing state). The cct Debounce is programmable within the range 20–1000
milliseconds (0.02–1 second); the default is 300 msecs. All entries are rounded up to the nearest 20 msecs.
NOTE: The value programmed in this option is the value allocated to the SYSTEM selection when programming
zone response time in option 52.
28 = Online Print
This parameter is used to select the print mode required when connecting a serial printer to the GX-Series
panel; there are two options:
0 = disabled (default): system only prints specific details at the user's request. The printer can be
connected and disconnected at any time as required;
1 = enabled: this option switches the printer to on-line mode and requires that a printer be
continuously connected to the system. Events are printed as and when they occur. The events printed
are controlled by parameter 29 = Online Level.
NOTE: If Online Print is enabled, the event log and other options will not be printed at the user's request. The
parameter must be disabled to permit all other print options to operate.
29 = Online Level
The On-line Level parameter determines the level of events that are printed when parameter 28 = Online
Print is enabled:
0 (default) - basic print [setting (arming), unsetting (disarming), alarms]
1 - full print excluding access events [setting (arming), unsetting (disarming), alarms, modifications,
technical details].
2 - full print including access events [all logged events].
3 - MAX (access control) events only [only card events].
4 - Basic Print plus access events [option 0 + access events].
30 = Video
This parameter determines the number of activations that must occur on any of the zones programmed as
Video, in a single set (armed) period, before a full alarm occurs; there is no time limit on the period between
activations. The Video parameter is programmable within the range 1–9 activations; the default is 2. The
video output occurs on every activation but a full alarm does not occur until the programmed number of
activations is reached. The Video zones activation counter is reset when the system is unset (disarmed).
NOTE: The activations of the Video zones are cumulative - the counter is incremented each time any Video
zone in the group is activated.
This parameter can be assigned a different value for each group.
GX-Series Control Panel Installation and Setup Guide