Honeywell GX-Series Installation And Setup Manual page 188

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
Ev
SIA Event
Log
Description
Event
DCM EVENT
DT
Door propped
DOOR PROP
E - System Trouble
ER
Mod Removed
REMOVED
F - Fire
FA
Fire Alarm
FIRE+
FB
Fire Bypass
OMITTED
FORCEOMT+
FJ
Fire Troub rest
LOW RES-
HIGH RES-
FR
Fire Restoral
FIRE-
FT
Fire Trouble
LOW RES+
HIGH RES+
FU
Fire Unbypass
FORCE OMT-
FX
Fire Test
FIRE
SOAK TEST
G - Gas (Custom SIA - See Note 2)
GA
Alarm
Note 1
GB
Bypass
OMITTED
FORCEOMT+
GJ
Trouble Rest
LOW RES-
HIGH RES-
GR
Alarm Restore
Note 1
GT
Trouble
LOW RES+
HIGH RES+
GU
Unbypass
FORCE OMT-
H - Holdup
HA
Holdup Alarm
PA SILENT+
PA DEL/SL+
DURESS
PA UNSET+
HB
Holdup Bypass
OMITTED
FORCEOMT+
HJ
Hold Troub rest
LOW RES-
HIGH RES-
HR
Hold Restoral
PA SILENT-
PA DEL/SL-
PA UNSET-
HT
Holdup Trouble
LOW RES+
HIGH RES+
HU
Hold Unbypass
FORCE OMT-
J - Wrong code, Time changed
JA
Code Tamper
WRONG CD
Invalid Code
INVALID CD
JL
LOG 90%
JR
TIMER A
TIMER B
AUTOTIMER
LOCKTIMER
JT
Time changed
NEW T/D
Log Event
Description
Invalid Card Reader Lockout USER
Access Door left open
Module Removed
Fire zone alarm
Fire zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
Fire zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
Fire zone tested
Soak test fire zone act
zone in alarm
zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
PA Silent zone alarm
PA Delay Sil.zone alarm
Duress with code
PA Unset zone alarm
Holdup zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
PA Silent zone restored
PA Delay Sil.zone rest.
PA Unset zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
Wrong code alarm act.
Invalid Code entered
Time/Date modified
B-4
Ev Type
Trigger
16.LOG
10.SETTING
17.MAXTAG
MOD.
4.SECURITY
MOD
TAMPER
ZONE
6.FIRE
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
6.FIRE
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
ZONE
NOT SENT
ZONE
NOT SENT
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
ZONE
1.PA/DURE
ZONE
1.PA/DURE
USER
1.PA/DURE
ZONE
1.PA/DURE
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
1.PA/DURE
18.ZN RESTO
ZONE
1.PA/DURE
18.ZN RESTO
ZONE
1.PA/DURE
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
MOD.
9.TAMPER
MOD.
ALWAYS TR
MISC
Always TR
MISC
NONE
MISC
NONE
MISC
NONE
MISC
NONE
USER
ALWAYS TR
3
Contact
ID Event
421
426
532
110
573
573
380
380
110
380
380
573
None
None
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
Note 1
122
122
121
122
573
573
380
380
122
122
122
380
380
573
461
None
632
0
0
0
0
625

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents