Option 66 – Pre-checks
The Pre-Check option provides added system security by alerting the user to zones that may not be
operating correctly.
NOTE: Pre-check does not operate when the system is in the engineer mode.
Testing Zones
The Entry/Exit Horns beep once when each zone is tested. As each zone is successfully tested, the keypad
indicates the number that remain to be tested. When the last zone is successfully tested the Entry/Exit
Horn sounds twice and the keypad displays 0 CHECK ZONES; press the ent key to resume the system
routine.
1 = Mode
The Mode determines the pre-check level that the selected zones are subjected to before the system can
set. The Mode is selected from one of the following:
1. Disabled (default): the pre-check option is disabled; even if zones are selected, they are not
checked.
2. Warning: when the setting (arming) routine is started the user is informed of the number of
selected pre-check zones that have not been activated since the system was unset (disarmed);
press the A> or <B keys to view the zones. Press the ent key to continue the setting (arming)
routine. The zone that have not been activated do not have to be tested.
3. Autocheck: when the setting (arming) routine is started the user is informed of the number of
selected pre-check zones that have not been activated since the system was unset (disarmed)
and a warning is sounded; press the A> or <B keys to view the zones. These zones must be
tested before setting (arming) can be resumed.
4. Forced Check: when the setting (arming) routine is started the keypad indicates the number of
pre-check zones t hat are on the system; to view the pre-check zone addresses press the A> or
<B keys. All of the preselected zones must be tested before setting (arming) can take place.
2 = Select Zones
On selecting 2 = Select Zones, the address and function of the first zone on the system is displayed.
Move to the required zone by pressing the A> or <B keys or by entering the zone address. To toggle the
status of the precheck attribute of the zone press the # key; the keypad indicates that the zone is
included in the pre-check by displaying PRE-CHECK ZONE. Select other zones to be pre-checked in
the same way. Once all of the zones have been selected, press the esc key.