GX-Series Control Panel Installation and Setup Guide
44-46
Not used.
47 Vibration
The Vibration function is continuously operational and is designed for use with vault sensors. Vibration
zones can be block omitted (block bypassed) using menu option 11 = Omit Zones. If the zone selected to be
omitted from the system is a Vibration zone, then all zones programmed with this function are omitted.
NOTES
1. All Vibration zones in all groups are omitted when any Vibration zone is omitted. The user code
does not have to have access to all of the groups.
2. Vibration zones remain omitted until a single Vibration zone is manually reinstated. The unsetting
(disarming) of the system does not reinstate omitted Vibration zones.
48-51 ATM-1, ATM-2, ATM-3 & ATM-4
There are four ATM (Automatic Teller Machine) zone types. These zone functions are continuously
operational and are designed for the special maintenance and restocking requirements of ATM's.
A single ATM zone type can be omitted for the duration of the period entered in the ATM Timeout
parameter (option 51.39). The ATM Delay parameter (option 51.38) determines the delay before the
selected ATM zones are omitted once selected by an ATM code. Each of the zones ATM-1 to ATM-4 zones
activates a corresponding ATM output.
NOTE: The relevant ATM outputs are activated as soon as the ATM Delay expires.
On entering an ATM code, the system prompts for one of the ATM zone types to be selected; to select the
ATM zone type to be omitted use the A> or <B key or enter the number of the ATM zone type. Once the
zone is selected, the keypad indicates the DELAY ACCESS - the number of minutes remaining until the
ATM zones are omitted. Once the zone is omitted, the initiating keypad indicates the ACCESS TIMEOUT
– the number of minutes remaining until the selected ATM zones are reintroduced to the system. The
Entry/Exit Horns sound a warning ten and five minutes before the zones are reinstated.
The omitted ATM zone type can be reinstated at any time, or the omit period can be extended by the ATM
user code. Enter the ATM code and press the ent key; the system prompts for 1 = RESET ACCESS or 2 =
ABORT ACCESS. Press 1 to restart the ATM Timeout or 2 to reinstate the omitted ATM's.
NOTE: Only one ATM zone type may be omitted at any time.
52 Alarm Extend
The Alarm Extend function is identical to the Urgent function, with the exception that if the zone is open
(and has not been previously omitted) at the end of the bell duration (refer to option 51.1 =
PARAMETERS.Bell Time) it immediately activates another full alarm condition. Alarm Extend zones
can only be omitted by option 11 = OMIT ZONES.