Unsetting (Disarming) the System Using a PIN

During the disarming procedure, initiated by the opening of FINAL or ENTRY zone on a set (armed) group,
the system is unset (disarmed) by entering the user code followed by the A> key.
If the user does not have group choice, all of the groups assigned to the code are instantly unset
(disarmed).
If the user has group choice only the group that the FINAL or ENTRY zone is assigned to is unset
(disarmed); all of the other groups remain set (armed). The system displays the set status of the
remaining groups and prompts for the required groups to be unset. To unset the required groups
press the relevant number keys — the S or P (Set or Part Set) changes to flashing U — and then
press the ent key.
When the system/group is unset (disarmed) three short beeps are emitted to advise the user that the
system/group is unset.

Engineer Unsetting (Installer Disarming)

The Engineer (Installer) can only disarm a system that was set (armed) using the Engineer code. The
Engineer code cannot be used to disarm a system that was set by a user code.

Keyswitch Setting (Arming) Options

Zones programmed as KEYSWITCH can be used to full set, part set and disarm the system. Refer to option
52 = PROGRAM ZONE.
Setting (Arming) the System with a Keyswitch
The KEYSWITCH starts the setting (arming) procedure of each of the groups assigned to the keyswitch
zone. At the end of the exit time, or when the setting procedure is terminated by a FINAL or PUSH-SET
zone closing, the ENTRY/EXIT HORN outputs and keypad buzzers become silent for four seconds, then
emit two long tones to confirm that the system is set.
NOTE: If the KEYSWITCH has its Part attribute enabled (refer to option 52 = PROGRAM ZONE) then the
KEYSWITCH part sets the system.
Unsetting (Disarming) the System with a Keyswitch
Activating the KEYSWITCH when the group that it is assigned to is set instantly disarms the group. All
other groups which have been "starred" to the KEYSWITCH are not affected and remain set.

Setting (Arming) the System with Proximity Cards

For access control readers, a function button or triple swipe will be required to activate the card function.
If the card user has a keypad assigned, the function will be shown as the assigned keypad. If the card user
has no keypad assigned then all keypads in the group assigned to the card user will show "Press any Key". If
a key is pressed the keypad containing the key to be pressed will show the card held function. If no keys are
pressed all keypads in the group(s) allocated to the card will show the card held menu function. If the card
user has group choice all groups available to the user will be displayed on the keypad. The user must select
the groups to be set/unset/part set using the appropriate number keys, as per normal PIN users. If the card
user has no group choice then the card held setting (arming) function will commence automatically.
Unsetting (Disarming) the System with Proximity Cards
The system or groups can be unset (disarmed) using proximity cards with the access control readers.
If the unsetting (disarming) procedure has been started by activating a Final or Entry zone then, swiping
the card will unset (disarm) the system. If the card user has group choice then, only the group assigned to
the Final or Entry zone will be unset (disarmed). All other groups available to the user will be displayed on
the programmed/selected keypad.
NOTE: The reader module must have common groups to the proximity card user to allow the card held function
to be activated.