3 = No Code/Notice
This enables a remote servicing session without the need for a Service PIN code and the panel's
remote servicing notification message. This option uses the start and end times programmed in
menu 47.4.2.1 and 47.4.2.2 respectively.
7 = Service Pin
This is a 6-digit numeric Service PIN code (default 987654), which initiates an automated call to the Remote
Servicing application. The Service PIN code can only be changed from Remote Servicing and sending the
Service PIN code to the panel via the Send Remote Access Start Code. The Service PIN code cannot be
the same as any other user codes on the system.
This option is only available when option 47.4.6.1 (schedule) is greater than 0 and when option 47.4.6.2.1
(code only) is enabled.
8 = Send Panel ID
When a remote servicing connection is established, this option allows panel identification and
authentication. When enabled, the following sequence of events occurs. Once a remote servicing connection
is established, whether panel or PC initiated, the panel delays for a period as determined by Delay Time for
incoming information from the remote servicing package.
If a valid control character is received by the panel within the delay period, the panel transmits an identity
string. If no character is received during the delay period the call is terminated.
9 = Delay Time
This is the time that the panel delays for incoming information from the remote servicing package. The
delay time can be set from 3-10 seconds. The default is 3 seconds.
GX-Series Control Panel Installation and Setup Guide