UL609 Local Mercantile Premises
1. All zones must be configured for single EOLR supervision detection.
2. Attach a Listed door tamper switch (supplied) to protect the cabinet door. Wire the supplied tamper switches
to the terminal block labeled lid tamper on the main control board. See SOC label for wiring details. Lid
tamper zone on the panel is defaulted enabled.
3. Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds.
4. All unused knockouts must be plugged (use the supplied disc plugs and carriage bolts).
5. Must be used with a Listed burglar alarm sounding device/housing. Depending on the application, a
compatible listed sounding device enclosure may also be required.
UL365/UL1076 Police Station Connected Burglar Alarm
Follow the instructions for UL609 local installations given above.
For Systems without Line Security:
You may use the control panel's main dialer alone, or the E080-2 Ethernet Module alone.
Program either the dialer or the E080-2 Ethernet Module to send Burglary Alarm, AC Failure, Low Battery,
Communicator Test Reports, Closing Acknowledge signal, Telco Line Failure to report via Ethernet,
Heartbeat Failure to report via Dialer, and Opening/Closing Reporting.
For Systems with Line Security:
The dialer must be used in conjunction with the E080-2 Ethernet Module.
Program both the dialer and the E080-2 Ethernet Module to send Burglary Alarm, AC Failure, Low Battery,
Communicator Test Reports, Closing Acknowledge signal, Telco Line Failure to report via Ethernet,
Heartbeat Failure to report via Dialer, and Opening/Closing Reporting.
UL1610 Central Station Burglary Alarm
Follow the instructions for UL365 local installations stated above, and follow the additional guidelines below.
Note: UL Listed Bell is not required for UL1610 Central Station Installations.
Dual Line Transmission:
Both the control panel's dialer and the E080-2 Ethernet Module are required for Dual Line Transmission.
Program both the dialer and the E080-2 Ethernet Module to send Burglary Alarm, AC Failure, Low Battery,
Communicator Test Reports, Closing Acknowledge signal, Telco Line Failure to report via Ethernet,
Heartbeat Failure to report via Dialer, and Opening/Closing Reporting.