GX-Series Control Panel Installation and Setup Guide
Option 67 – Remote Reset
The Remote Reset option allows a user to perform an engineer reset authorized by the Alarm Receiving
Center (ARC). In the event of an alarm that requires an engineer reset, the keypad displays a number,
which, when quoted to the ARC is decoded and exchanged for a new number. When this new number is
entered it resets the GX-Series panel. Entering the engineer code also resets the GX-Series panel.
NOTE: The alarm conditions that require to be reset remotely must have the appropriate System Reset,
Tamper Reset or PA Reset parameters programmed for engineer reset (type 3.7). Each alarm activation
generates a random number, therefore, the number required to reset the panel changes each activation. As
ARCs have different decoding equipment, the appropriate reset system must be selected from the following
Remote Mode options:
0 = OFF (default).
1 = SMS - Southern Monitoring Service (4 digits).
Option 68 – Menu Access
The Menu Access option is used to assign access types to each of the menu options. This allows code types
2.3 – 3.6 to have access to menu options to which they would normally have insufficient access rights.
On selecting this option, 11 = OMIT ZONES is displayed along with the current code types assigned (3456
default).
e v e l s
3 4 5 6
1 1 = O M I T Z O N E S
Use the A> or <B key to select the required menu option or enter the option number directly and press the
ent key. The currently assigned types appear displayed on the top line of the display. The type maps default
to the standard access. To modify the types, press the required number keys; this toggles the access type
numbers on the bottom line of the display on and off.
e v e l s
3 4 5 6
> - - 5 -
Press the ent key to save the programming and return to the previous menu level. If the level is assigned to
the option the number is displayed, if it has been removed a dash (–) is displayed.
For example, type 2.5 5 codes can be given access to menu 42 which would allow them to allocate codes.
e v e l s
- - - 6
4 2 = C O D E S
Users can only allocate codes up to the type that they have been assigned. A type 2.4 user cannot assign a
user code as type 2.5.
NOTE: The following menu access types are fixed: option 48 = DATELOCK level 3.6, and option 68 = MENU
ACCESS engineer access (type 3.7 and 3.8).
GX-091-V0
GX-092-V0
GX-093-V0
6-126