Honeywell GX-Series Installation And Setup Manual page 190

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
Ev
SIA Event
Log
Description
Event
FAULT RST
PF RESET
P - Panic
PA
Panic Alarm
PA+
DELAY ALM+
PB
Panic Bypass
FORCEOMT+
PJ
Pan Troub rest
LOW RES-
HIGH RES-
PR
Panic Restoral
PA-
DELAY ALM-
PT
Panic Trouble
LOW RES+
HIGH RES+
PU
Panic Unbypas
FORCE OMT-
Q - Assist (Custom SIA - see note 2)
QA
Alarm
Note 1
QB
Bypass
OMITTED
FORCEOMT+
QJ
Trouble Rest
LOW RES-
HIGH RES-
QR
Alarm Restore
Note 1
QT
Trouble
LOW RES+
HIGH RES+
QU
Unbypass
FORCE OMT-
R - Remote,Log,Test
RB
REM LOG
REM RESET
REM ID
REM COPY
REM OVRWR
REM MSG
COPY SITE
OVWR SITE
RC
Relay closed
LINK-
LOG-
LOG DELAY-
CUSTOM A-
CUSTOM B-
EXITGUARD-
RD
Prog, denied
RMACCESS+
RO
Relay open
BELL FAIL
KEYSWITCH
LINK+
LOG+
LOG DELAY+
NOT USED
SET LOG
CUSTOM A+
CUSTOM B+
EXITGUARD+
PUSH SET
KSW RESET
SPARE
RP
Automatic test
AUTOTEST
RR
Power Up
MEMORY OK
RS
Prog, success
RM ACCESS-
REM CALL
RX
Manual test
ENG TEST
Log Event
Description
PA zone alarm
PA Delay zone alarm
OMITTED
PA zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
PA zone restored
PA Delay zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
zone in alarm
zone omitted
Force omit after rearm
Restor zone resistance
Restor zone resistance
zone restored
Low resistance on zone
High resistance on zone
Unomitted after rearm
Link zone closed
Log zone closed
Log delay zone closed
Zone closed(Non alarm)
Zone closed(Non alarm)
Exitguard zone closed
Zone denied rem. acc
Bell fail zone opened
Link zone opened
Log zone opened
Log delay zone opened
Zone opend(Non alarm)
Zone opend(Non alarm)
Exitguard zone opened
Push set zone opened
Spare zone opened
Automatic test
Warm start of panel
Zone allowed rem acc
Remote call complete
Engineer test
Ev Type
Trigger
USER
20.FAULT
USER
20.FAULT
ZONE
1.PA/DURE
ZONE
1.PA/DURE
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
1.PA/DURE
18.ZN RESTO
ZONE
1.PA/DURE
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
ZONE
5.CUS ZON
ZONE
8.OMIT
ZONE
8.OMIT
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
5.CUS ZON
18.ZN RESTO
ZONE
15.TROUBL
ZONE
15.TROUBL
ZONE
8.OMIT
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
USER
NONE
MODULE
NONE
MODULE
NONE
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
14.MEN AC
ZONE
16. LOG
KS
NONE
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16. LOG
ZONE
16. LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
16.LOG
ZONE
NONE
KS
NONE
ZONE
16. LOG
EVENT
ALWAYS TR
EVENT
13.ELEC ST
ZONE
14.MEN AC
MOD
14.MEN AC
USER
ALWAYS TR
B-6
Contact
ID Event
313
313
120
120
573
573
380
380
120
120
380
380
573
Note 1
573
573
380
380
Note 1
380
380
573
0
0
0
0
0
0
0
0
150
150
150
150
150
150
553
150
150
150
150
150
150
150
150
150
150
150
150
150
602
305
553
412
601