Test options

Walk Test [31, Quick Menu 5]

Walk Test menu
31 = Walk Test
û
1 = View – not used
2 = Activate
û
1 = Silent
2 = Audible
View [31.1] Not used
Activate silent test on all zones [31.2.1.1] &
Activate audible test on all zones [31.2.2.1]
Use these options to starts an immediate walk test on all zones that have the omit attribute
enabled (refer to Program Zones [52]). Non-omittable zones are not included and remain
active throughout the test. If all zones are non-omittable NO ENTRIES is displayed.
Activate silent test on selected zones [31.2.1.2] &
Activate audible test on selected zones [31.2.2.2]
Use these options to select specific zones to test.
1.
Navigate to a zone you want to test (use
2.
Press
to toggle the test status to TEST.
#
3.
Repeat the steps above until you have selected all the zones you wish to test.
4.
Press
to start the test.
ent
Alternatively:
1.
Press
to include all zones.
2.
Navigate to any zones you wish to exclude (press
3.
Press
to start the test.
ent
û
1 = Test all Zones
2 = Selected Zones
û
1 = Test All Zones
2 = Selected Zones
A
Walk Test [31, Quick Menu 5]
or
or type a zone number).
B
to exclude a zone).
#