GX-Series Control Panel Installation and Setup Guide
4 = Conn. Retry
If the attempt to initiate a remote servicing call fails, the panel can be programmed to do repeat dial
attempts. There are three further options:
1 = Retry Interval
The dial attempts can be programmed to occur from 0-60 minutes. Setting the value to 0 disables the
feature. The default setting is 30 minutes.
2 = Retry Duration
The length of time that the panel tries to do a remote servicing call can be programmed from 0-24 hours.
Setting the value to 0 disables the feature. The default setting is 6 hours.
3 = Redial Mode
In the event of a remote servicing session terminating unexpectedly, the panel enters one of the three
programmable modes that follow.
0 = Off
The panel does not try to re-establish a connection.
1 = Retry
The panel initiates a remote servicing call to re-establish a connection. The retries will be as per
option 47.4.4.1 (Retry Interval) and 47.4.4.2 (Retry Duration).
2 = Direct
The panel access mode changes to allow direct access for 30 minutes. This mode operates as per
option 47.1=Service when Direct Access is selected.
5 = Control Upload
This option controls whether a connection is established when only engineer or user programming data is
uploaded. This feature has three options.
1 = Eng Prog
Only initiates a connection when engineering programming has been modified.
2 = User Prog
Only initiates a connection when user programming has been modified.
3 = Either
Initiates a connection when either engineering or user programming has been modified.
6 = Remote Maint
This option controls the mode for automatically initiating communications for remote routine inspection and
panel programming is uploaded. There are two sub-options that control this:
1 = Schedule
This option controls the schedule for the initiation of communication for remote routine inspection. The
schedule can be set from 0-365 days. The default is 0 days which disables the function.
2 = Advice
This option controls the method by which communication is initiated. It can be initiated automatically
by the schedule programmed above or manually by user entry of the Service PIN code, with or without a
notification message. There are three options. The default value for each is disabled.
1 = Code Only
Entry of a Service PIN code automatically initiates a remote servicing connection to call back
number 1.
The Service PIN code can only be modified by remote users. When the Service PIN code is entered, it
resets any scheduled connection timers.
2 = Code + Notice
This enables the remote servicing notification timer, and display of remote servicing notification.
The remote service notification message is not displayed if the system is set (armed). It only becomes
active when the panel is unset (disarmed). The message REMOTE CALL INIT, A=SP PIN
ENTER is displayed on the keypad after entry of a valid manager type user code.
6-36