Honeywell GX-Series Installation And Setup Manual page 62

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
Access Log Information
The access log contains a reason why the door will not operate. These can be:
Not Grp Match
Reject Grp Set
Illegal Time
The keypad display in the access log also shows user information:
Press the # key to view the reason for rejection:
The line number for proximity card readers is in the format, for example 0013:
00 = not required
1 = line number 1
3 = Address number 3.
Access Log Print and Store Option
The Access Doors (Log) is printed on-line and stored in the event memory.
The Access Door Log print displays in the format of the Event Log and allows information to be accessed.
The format is as follows:
HH:MM_XXXXXXXXXX_USR_NNN_UUUUUU_MYYYY_—_ (39 character display)
Where:
HH:MM = time in hour:minutes (5 characters). The date will be printed only at the beginning of every day,
that is midnight.
XXXXXXXXXX = access message (10 character) Valid, Invalid Card, Reject Card
USR = User (3 characters)
NNN = User number to which proximity card is assigned (3 characters)
UUUUUU = User descriptor (6 characters)
M = Proximity reader address (1 character)
YYYY = DCM physical address- (5 characters: e.g., M1072 = line 1, reader address 07, reader 2)
- (dash) = unused character slot
__ (underscore) = this represents a space and is not printed or displayed in the access log.
For example: A valid card read at DCM 1072 from the card held by user 020, name Albert, at 13:48 would be:
13:48 Valid USR 020 Albert M1072 –
Descriptor
The descriptor is a maximum of 16 characters entered in the DCM Parameters (69.3.1).
Engineer Mode
On accessing the Access Doors option in Engineering mode, each on-line DCM module displays its address
by lighting the appropriate LEDs. To help the engineer identify each of the DCM modules, the keypad
displays a graphic representation of the DCM module address. By matching the
image to the LEDs on the DCM, the engineer can identify each DCM module on the system.
1:
THU 26 APR
U S E R
1
LINE NUMBER
02
Reject Grp Set
6-16
R e j c t
GX-070-V0
DCM ADDRESS
READER NUMBER
Grp A
GX-071-V0
(LED off) and ■ (LED on)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents