Honeywell GX-Series Installation And Setup Manual page 88

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide
08 = No. Re-Arms
The Number of Re-arms parameter determines the number of times that an armed system can re-arm the
bells following an alarm activation. The default setting is 9 (infinite) with a programmable range of 0 – 9,
where 9 is infinite re-arm. If the option is enabled, then the system re-arms at the end of the programmed
confirm time - only if all zones are closed or are open and can be omitted, or if the Omit all force is enabled.
The intruder output remains active until a system re-arm occurs.
Zones that are open at the end of the bell time must be omittable (Omit attribute enabled); the re-arm will
omit these zones. The complete zone circuit, including the tamper facility, is omitted. Refer to menu option
52 = PROGRAM ZONES for details on enabling the zone omit attribute.
NOTE: If an open zone is not omittable, then the system will not re-arm, unless parameter 09 = Omit All is set to 2.
09 = Omit All
This option determines if activated zones can be omitted at re-arm as described above.
0 = Disabled
1 = Omit All When set to 1 (enabled), omits any omittable zones that are open at re-arm. The complete
zone circuit including tamper is omitted.
2 = Force. Same as Omit All but omits zones whether omittable or not.
Refer to menu option 52 = PROGRAM ZONES for details on enabling the zone omit attribute.
10 = Key "0"
Key 0 on the keypad can be assigned to operate as a Push-set zone function; this will terminate the timed
setting (arming) procedure. When the option is set to 1 (enabled), pressing key 0 during the exit time
completes the setting (arming) of the system. The default is 0 (disabled).
NOTE: Key 0 must be pressed only on the keypad used to start the setting (arming) procedure.
11 = Local Part
When the Local Part parameter is set to 0 (disabled - default setting) the Intruder outputs are disabled
when the system is part set (part armed); the programmed bell delay is overridden. This is normally used to
prevent the communicator from dialing the Alarm Receiving Center (ARC).
If the Local Part parameter is set to 1 (enabled) the Intruder outputs activate if an alarm condition occurs
when the system is part set (part armed).
Option 2 (SIA part off) is identical to option 1 with the exception that when the alarm format of the telecom
module is set to SIA then the part setting (arming) and unsetting (disarming) of the system is not signaled
to the ARC.
This parameter can be assigned a different value for each group.
12 = Banner
This option can be used to customize both the top and bottom lines of the banner display. Press 1 to select
the TOP LINE or 2 to select the BOTTOM LINE; the display is written using the alpha-numeric assembly
method:
* erases characters;
# selects upper case, lower case or library;
A> <B selects alphabet character/words;
000–500 selects alphabet character or words;
ent positions selected characters/words;
esc accepts the programming and returns to the previous level; exits from the option.
The banner is displayed when the system is in the normal mode [set/unset (armed/disarmed)].
13 = PA (Personal Attack) Delay
This parameter determines the delay between the activation of a PA Delay or PA Delay Silent zone and
the alarm sounding and signaling a PA via the communicator. The PA Delay is programmable within the
range 1–60 seconds; the default is 60.
6-42

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents