5 = Batch End
This option determines the user number where enrollment ends.
6 = Batch DCM Rdr
This option determines the DCM reader used for enrollment. Pressing the * key returns the system to
the default of any reader.
7 = Template User
This option chooses a user to be a template whose access authority and non-unique attributes are
applied to other users on the system when using the 1 = Add Batch function.

Option 43 - Dlight Saving [Quick Menu Option 9]

Daylight Savings time by default begins on the second Sunday in March and ends on the first Sunday in
November. The default values can be viewed and modified here.
The operation of the Daylight Savings Time option is as.follows: At 02:00 hours on the Start date, the
system clock advances to 03:00 hours. At 02:00 hours on the End date, the system clock goes back to 01:00
hours.
The Start and End dates can be reprogrammed by authorized user codes. Press the A> key to modify the
Start date or the <B key to select the End date. The new date must be a valid four digit number in the
month/day format (MM/DD).
Option 44 – Trace
This option provides a record of the most recent alarm activation. The Trace option records the details of
the setting (arming) and unsetting (disarming) of the system immediately before and after the alarm
activation and the first five events occurring during the alarm activation. This information is maintained in
the trace until the next alarm activation. On entering the option pressing the A> and <B keys steps through
each of the seven trace entries.
Pressing the # key while viewing the Trace option displays additional information about certain events –
user events reveal the keypad, user level and current group; alarm events reveal the zone descriptor if
programmed.
The currently displayed trace can be printed out by pressing the * key; pressing the esc key aborts the
printout.
NOTE: A serial printer must be connected to the GX-Series panel via the on-board serial port, a printer interface
module or an RS232 interface module.
Option 45 – Timer Control
45.1 = View
This option allows the weekly schedules programmed in option 65.1 to be viewed:
1 = Weekly Schedule
Use the A> and <B keys to scroll through each of the programmed schedules and on/off times.
2 = Timer Outputs
This option allows the Timer- A and Timer-B outputs with on/off times, allocated in option 65.2, to be
viewed.
3 = Autoset
Use the A> and <B keys to scroll through the groups to select one (optional) and also to view the time
schedule allocated per group.
4 = Lockout
Use the A> and <B keys to scroll through the groups to select one (optional) and also to view the time
schedule allocated per group.