Honeywell GX-Series Installation And Setup Manual page 119

Gx series;
Table of Contents

Advertisement

01 Bells (Latch)
The Bells output is activated on a full alarm event when the system is set (armed). This output is subject to
the Bell Time, Bell Delay and No. Rearm parameters.
02 Strobe (Latch)
The Strobe output is activated on a full alarm event during the set (armed) state. This output is subject to
the Bell Delay. The Strobe output follows the Bell Time, but latches on after the last rearm.
03 PA (Latch)
The PA output is activated whenever any of the PA zone types activate. The output is not subject to the
Rearm parameter; it latches on remains active until a valid code, with the appropriate PA Reset level, is
entered.
04 Intruder (Latch)
The Intruder output is activated on a full alarm event during the set (armed) state. Dependent upon the
programming of parameter 51.56 Force Restore the intruder output restore is either subject to the Confirm
Time Window + unset or entry of a valid code with the appropriate system reset level. Refer to the 51.56
Force Restore description for further details.
05 Tamper (Latch)
The Tamper output is activated whenever a circuit tamper or lid tamper occurs. The output is not subject to
the Rearm parameter: it latches on and remains active until a valid code, with the appropriate Tamper
Reset level, is entered.
The output is also activated on the first entry of the engineer code when accessing engineer mode.
NOTE: The Tamper output is not activated on the GX-Series 512 when engineer access is authorized by the
user.
06 24 Hours
The 24 Hours output is activated whenever a 24 Hour zone is activated. The output is not subject to the
Rearm parameter: it latches on and remains active until a valid code, with the appropriate System Reset
level, is entered.
07 Reset (Latch)
The Reset output type is used as a control line output to latch, freeze and reset movement detector LEDs.
08 Switch DC (Pulse)
This Switch DC output is used to power detectors that require a momentary power interruption to reset
them, for example, break glass or vibration detectors. This output reverses its polarity (changes from 0V to
12V) for the period of the Pulse output mode when the setting (arming) procedure has been initiated.
NOTE: When installing detectors that require to be powered from a Switch DC output, connect the positive lead
of the detector to the 12V terminal of a power supply and the negative lead to SwitchDC output terminal.
Do not change the Output Polarity to 1=Neg: it must remain as positive polarity.
NOTE: The maximum output is 12 V at 400 mA total.
09 Set (Reflex)
The Set output is activated when the assigned groups on the system are set (armed). This output is a Reflex
(follow) output and follows the set (armed) and unset (disarmed) status of the groups.
10 Engineer (Reflex)
The Engineer output is activated while the engineer mode is being accessed.
11 Spare (Latch)
The Spare output has function: it is used to designate outputs that are not being used on the system.
12 Ready (Reflex)
The Ready output is active when all zones in the system (group) are closed. This output activates in both
the unset (disarmed) and set (armed) conditions.
GX-Series Control Panel Installation and Setup Guide