Zone Function
01
Final
02
Exit
03
Intruder
04
24 Hours
05
Security
06
Dual
07
Entry
08
Push Set
09
Keyswitch
10
Secure Final
11
Part Final
12
Part Entry
13
PA
14
PA Silent
15
PA Delay
16
PA Delay Silent
17
Link
18
Spare
19
Fire
20
Tamper
21
Bell Tamper
22
Beam Pair
23
Battery Low
24
Line Fail
25
AC Fail
26
Log
01 Final {Not for UL installations}
Zones programmed as Final initiate the unsetting (disarming) procedure and terminate setting (arming)
procedure; opening the Final zone when the system or group is set (armed) starts the entry timer; opening
and then closing the Final zone during the exit procedure sets the system or assigned groups, providing all
the zones are closed. The opening (+) and closing (–) of Final zones during the setting (arming) and
unsetting (disarming) procedures are recorded in the event log. Pressing the * key when programming a
Final zone doubles the entry time of the group.
Opening a Final zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
NOTE: The termination feature of a Final zone can be extended to terminate the setting (arming) of multiple
groups by pressing the * key when assigning a group to the zone. Refer to the Star * Group Function.
02 Exit
Zones that protect the entry and exit routes are programmed as Exit. During the setting (arming) and
unsetting (disarming) procedures Exit zones have a non-alarm operation. If the Exit zone is activated while
the system is set (armed) - without the unsetting (disarming) of the group being initiated - an Intruder
alarm condition is activated.
Opening an Exit zone during the exit time is reported on the keypad as an open zone; the Entry/Exit
Horns bleep rapidly to indicate that the zone is open.
NOTE: The Exit zone can be assigned to multiple groups by pressing the * key when assigning a group to the
zone. This allows an Exit zone to be activated in a group which is not currently being unset (disarmed)
without activating an Intruder alarm. Refer to the Star * Group Function.
GX-Series Control Panel Installation and Setup Guide
Table 6-16. Available Zone Functions
6-57
Zone Function
27
Remote Access
28
Video
29
Video Exit
30
Intruder Delay
31
Log Delay
32
Set Log
33
Custom-A
34
Custom-B
35
Exitguard
36
Mask
37
Urgent
38
PA Unset
39
Keyswitch Reset
40
Bell Fail
41
Intr Low
42
Intr High
43
PSU Fault
44
Not Used
45
Not Used
46
Not Used
47
Vibration
48
ATM-1
49
ATM-2
50
ATM-3
51
ATM-4
52
Alarm Extend

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents