Option 52 - Program Zones - Honeywell GX-Series Installation And Setup Manual

Gx series;
Table of Contents

Advertisement

Option 52 – Program Zones
This option is used by the engineer to modify the programming of the zones on the system. The option also
allows the attributes of the zone to be changed. The programmable options are shown in the table that
follows:
Attributes
1
Function
2
Descriptor
3
Chime
4
Omit
5
Part
6
Resp. Time
7
Custom SIA
8
Activity Mon.
9
Res. Select
10
Group
Note: Groups only appear if the Group option is enabled (refer to option 63.1 =
OPTIONS.Groups).
Selecting Zones
On entering the option, the first zone on the system is displayed; the zone address, function and group
assigned are displayed on the top line, the descriptor is displayed on the bottom line. Pressing the # key
toggles the descriptor to reveal the status of the chime, omit and part attributes. If the attribute is enabled,
the initial attribute letter is displayed, if it is disabled, a dash (–) is shown. For example, chime, part and
omit enabled display as COP, if omit is disabled the display would be C – P.
From the display of the first zone, any zone on the system can be displayed by pressing the A> or <B keys or
by entering the address of a specific zone.
The zone is selected for programming by pressing the ent key; the first zone programming attribute
1=Function is displayed.
Attributes
The attributes can be stepped through by pressing the A> or <B keys or directly selected by pressing the
attribute number (1–8). Once the required attribute is on display, press the ent key to gain access for
modification.
Once the attribute has been assigned press the ent key to save the programming and return to the attribute
selection level.
Pressing the esc key at any time when assigning attributes 1 and 3–10 to a zone aborts the programming
and returns to the attribute selection level. Pressing the esc key when assigning a descriptor to a zone saves
the assigned alphanumeric text and returns to the attribute selection level.
1 = Function
Entering the Function attribute displays the address and the current function of the selected zone along
with the zone function reference number. The zone functions can be stepped through, forwards or
backwards, using the A> and <B keys. Alternatively a zone function can be directly selected by entering the
zone function reference number, for example, entering the 19 displays zone function 19 = FIRE.
Once the required zone function is displayed, it is assigned to the zone by pressing the ent key.
GX-Series Control Panel Installation and Setup Guide
assign zone type
16 character (max.) alpha-numeric description
enabled = momentarily chime effect if zone opened while unset (disarmed)
enabled = zone can be omitted (bypassed)
enabled = zone included in part setting (part arming) of system
Modify circuit debounce time
Select SIA event
Selects criteria for zone activity checking
Selects resistance range for zone
assign zone to a single group on the system
Table 6-13. Zone Attributes
6-53
Description