Mounting The Control Cabinet; Installing The Cabinet Lock - Honeywell GX-Series Installation And Setup Manual

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide

Mounting the Control Cabinet

To mount the control cabinet, perform the following steps:
Do not attempt to remove the knockouts after the circuit board has been installed
Step
1.
Before mounting the circuit board, remove the metal knockouts for the wiring entry that you will
be using.
2.
Using fasteners or anchors (not supplied), mount the control cabinet to a sturdy wall in a clean,
dry area that is not readily accessible to the general public. The back of the cabinet has 4 holes for
this purpose.
To provide certificated burglary service for UL installations, refer to the special requirements and
U L
Figure 2-3. Cabinet Attack Resistance Considerations to follow.

Installing the Cabinet Lock

To install the lock, see Figure 2-2 and perform the following steps:
Step
1.
Remove cabinet door, then remove the
lock knockout from the door. Insert the
key into the lock.
2.
Position the lock in the hole, making
certain that the latch will make contact
with the latch bracket when the door is
closed.
3.
When correctly positioned, push the lock
until it is held securely by its snap tabs.
Mercantile Premises Listing Guidelines
The panel door must be supervised. Mount the clip-on tamper switch (supplied) to the cabinet's right
side wall and wire it to the cover tamper on the PCB. See Figure 2-4 for the location of the PCB terminal
block.
All wiring between the transformer and panel must be run in conduit. Remaining wires do not need to be
run in conduit.
All unused knockouts must be plugged using the disc plugs and carriage bolts (supplied), as indicated in
Figure 2-3.
Fasten the cabinet door to the cabinet backbox using the 15 one-inch-long Phillips-head screws
(supplied) after all wiring, programming, and checkout procedures have been completed.
Action
Action
HE K
POSITION
LO KED
PUSH
UNLO KED
ABINET DOOR
BOTTOM
Figure 2-2. Installing the Lock
2-2
PUSH
ON LO K
UNTIL IT
SNAP
IS SEATED
TAB
SE URELY
SNAP
TAB
STEP 1
STEP 2
GX-003-V0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents