Option 18 – Home Set (Arm) [Stay]
The Home Set option either fully sets or part sets the system. The system is:
fully set (armed) if the exit time is manually terminated via a Final or Push-Set zone operation;
part set (armed) if the exit time is allowed to expire.
Option 19 – All Set (Arm) [Away]
All Set allows a timed set (arming) of groups assigned to the user code without offering the choice of which
groups are to be set. No group choice is offered. The groups that are set (armed) when this option is selected
is determined by the keypad group restriction (refer to option 58.7 = KEYPADS.Groups):
If there is no keypad group restriction then all of the groups assigned to the user are set (armed) —
as long as there is at least one common group assigned to the keypad.
If there is a group restriction on the setting (arming) keypad, then only the groups that are common
to both the user and the keypad on which the menu option is selected are set. For example, a user
assigned groups 1, 2, 3, and 4 selecting the All Set option on a keypad assigned groups 2 and 3 will
only set (arm) groups 2 and 3.