GX-Series Control Panel Installation and Setup Guide
Subsequent high and low resistance readings from the same zone on the same day do not activate the output
if it has been reset by a valid user code.
NOTE: If a low resistance reading is followed by a high resistance reading, the Warning output activates on the
first occurrence of both activations.
34 Custom A (Latch)
The Custom-A output is activated whenever a Custom-A zone is activated.
35 Custom B (Latch)
The Custom –B output is activated whenever a Custom-B zone is activated.
36 Test (Pulse)
The Test output is activated at 12:00 hours each day for two seconds – the period of the Pulse can be
altered. This output can be used to perform a daily test on an external dialer or communicator connected to
the system.
37 Reset RQD (Latch)
The Reset RQD output is activated when a system, tamper or PA alarm has occurred that requires to be
reset by the engineer (type 3.7) code. Refer to option 51=PARAMETERS for details modifying the code
types assigned to the 06=System Reset, 07=Tamper Reset and 22=PA Reset parameters.
38 Mask (Latch)
The Mask output is activated whenever the zone resistance values returned by the RIO to the panel fall
within the range of the masked state (see Parameter 51.46, Zone Resistance). The output is not subject to
the Rearm parameter: It latches on and remains active until a valid group code (type 2 or above) is entered.
39 Valid Code (Reflex)
The Valid Code output is activated by the entry of any valid code. If the Output Mode assigned is Reflex
(follow), the output remains active while the user is accessing the menu and setting (arming) and unsetting
(disarming) the system. Once the menu is exited or the system sets or unsets, the output is restored.
40 Fail Set (Latch)
The Fail Set is activated if the system (or assigned groups) fails to set (arm) within the time assigned in
parameter 35=Fail to Set – refer to option 51=PARAMETERS.
41 Duress (Latch)
The Duress function is activated on entry of a Duress Code (any valid code followed by two #'s, or a code
assigned as a Duress Code using menu option 42 – Codes). The output is not subject to the Rearm
parameter: it latches on and remains active until a valid code (type 2 or above) is entered.
42 Illegal Code (Latch)
The Illegal Code is activated 60 seconds after an entry of a single Dual Code or a code which is entered
out with the Timer A and/or Timer B times assigned to it in menu option 42.1.4=CODES.User
Codes.Schedule.
43 NOT USED
44 Abort (Latch)
The ABORT output is activated when a valid code is entered during the Abort period on system entry.
45 Unset
The Unset output is activated each time the system (or group) is unset (disarmed). The default output
mode attribute is programmed as pulse, for two seconds. This can be used to activate a buzzer to notify a
user that the system has been unset, when using an RF fob.
46 Set Late (Latch)
The Set Late output is activated if the system has not been set (armed) by the programmed Monitor time –
refer to option 65.3.1=TIMERS.Autoset.Status.
6-76