Wiring Keyswitches; Wiring Terminator Buttons; Outputs - Honeywell GX-Series Installation And Setup Manual

Gx series;
Table of Contents

Advertisement

GX-Series Control Panel Installation and Setup Guide

Wiring Keyswitches

Latching or spring loaded keyswitches can be used to set (arm) and unset (disarm) the GX-Series panels;
option 52 = PROGRAM ZONES has provision to accommodate both types of transition. If the keyswitch
latches, the transition from 1 k• to 2 k• initiates the setting (arming) procedure of an unset (disarmed)
system, the transition from 2 k• to 1 k• instantly unsets (disarms) a set (armed) system. If the system is
already set (armed), then the transition from 1 k• to 2 k• has no effect. If the system is unset (disarmed),
the transition from 2 k• to 1 k• has no effect. This is programmed as a * Keyswitch in the PROGRAM
ZONES option. If the keyswitch is spring-loaded (returns to its normal position), the transition from 1 k• to
2 k• initiates the setting (arming) procedure of an unset (disarmed) system and instantly unsets (disarms) a
set (armed) system, the transition from 2 k• to 1 k• - the return to the normal position - has no effect. This
is programmed as a Keyswitch in the PROGRAM ZONES option.

Wiring Terminator Buttons

Zones programmed as Push-Set (terminator) buttons can be open going closed (2 k• to 1 k•) or closed going
open (1 k• to 2 k•). The first activation of the terminator button initializes its status to the system.
NOTE: The first activation of a terminator may not set (arm) the system as this can be the initialization routine. If the
system continues setting (arming), push the button again. The system will set (arm) on the second push. This
initialization only occurs on the first setting (arming). All subsequent setting (arming) routines set (arm) on the
first push of the terminator. The wiring of the terminator and keyswitch zone type is shown in Figure 2-16:
Keyswitch
zone
Push-set
zone

Outputs

The GX-Series control panel on-board outputs are detailed in the Table 2-9:
NOTE: The maximum current draw for the +12V AUX outputs is 1A, and for the switched AUX outputs is 400mA
(see TB1 – TB6 in Figure 2-4.) The total maximum load for output addresses 1001, 1003 – 1004 and
1011 – 1014 = 400 mA.
Output Address
Line 0
Default
Enable
1001
1001
1002
1002
1003
1003
1004
1004
1011
0011
1012
0012
1013
0013
1014
0014
Open - Closed
1k
1%
Figure 2-16. Terminator and Keyswitch Zone Wiring
Default Function
Bells
Transistorized
Strobe
Single Pole Change
Over Relay (SPCO)
PA
Transistorized
Reset
Transistorized
Set
Transistorized
Intruder
Transistorized
Confirm
Transistorized
Reset
Transistorized
Table 2-8. Outputs
1k to unset (disarm)
2k to set (arm)
1k
1%
OR
Closed - Open
1%
1k
1640 ft (500 m)
Type
Rating
12V, see note above
30V, 1A
12V, see note above
12V, see note above
12V, see note above
12V, see note above
12V, see note above
12V, see note above
2-14
1%
1%
GX-016-V2
Normal State
(with 3k3 pull-up)
Positive
De-energized
Positive
Positive
Positive
Positive
Positive
Positive

Advertisement

Table of Contents
loading