GX-Series Control Panel Installation and Setup Guide
2 = Save config
This option allows the panel configuration data to be saved to SPI Key. If selected the user is first
prompted for filename for the saved data. This can be up to 8 characters in length.
Once the filename has been entered the data save sequence is started. The keypad display gives an
indication of the progress until the configuration has been saved.
3 = Check space
If selected this option displays the available space left on the SPI Key. This will display the number
of free memory Kbytes left on the device, out of a maximum of 4096.
4 = Erase key
This option deletes all programming and returns the SPI key to the unformatted state. This option
should not be used.
NOTE: If replacing the software all users, other than the engineer at the keypad in use will be logged out
of the system. The keypad banner will display a warning of what is happening. The engineer will
be given a warning that the panel software is about to be replaced. It will take approximately 2
minutes to replace the software, during which time the keypads will go off line. Once
reprogrammed, the panel will restart.