Option 51 – Parameters
This option allows the engineer to modify the system functions. Options can be selected using the A> or <B
keys or by entering the two digit parameter number and pressing the ent key. The selected options can then
be programmed by using the A> key to increase or the <B key to decrease the values assigned to the
parameter; pressing the ent key accepts the new value and returns to the previous menu level. Any
parameters that differ from this procedure are indicated in the following paragraphs. The parameters also
prompt the engineer on which keys to press.
For example, press:
1 then 6 parameter 16 = Soak Time selected;
ent currently soak time is displayed along with the programmable range 07 (1–14) days;
08 value of the required soak time, the display shows the new value 08 (1–14) days;
ent accept the programming and return to 16 = Soak Time displayed.
NOTE: Default settings must be changed before programming in Menu Option 55 – Soak.
Assigning Parameters to Groups
Several of the parameters allow separate values to be assigned to the groups on the system. If groups have
been enabled, the relevant parameters prompt for a group to be selected; when selected, the value is
assigned to the group parameter using the procedure outlined in the previous example.
The parameters that permit group selection are indicated in the following paragraphs.
Parameter
01
Bell Time
02
Bell Delay
03
Abort Time
04
Exit Time
05
Entry Time
06
System Reset
07
Tamper Reset
08
No. Re-arms
09
Omit All
10
Key '0'
11
Local Part
12
Banner
13
PA Delay
14
KEY/SW Level
15
System Text
16
Soak Time
17
Restart
18
Stop Set
19
Part Alarm
20
Power Delay
21
Reset Mgr.
22
PA reset
23
Print Codes
24
Exit Alarm
25
Global Copy
26
Forced
27
cct Debounce
28
Online print
29
Online level
30
Video
31
Delay Alarm
32
Show Alarms
33
Secure Code
34
Comfort Time
35
Fail To Set
36
Battery Size
37
Standby Time
38
ATM Delay
GX-Series Control Panel Installation and Setup Guide
Groups
GX-Series
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
Table 6-8. System Parameters
Parameter
39
ATM Timeout
40
Not Used
41
Weekend Work
42
PIN Change
43
Not Used
44
Early Open
45
High Security
46
Res. Select
47
Set Confirm
48
Alarm Limits
49
Confirm Time
50
Not Used
51
Not Used
52
Not Used
53
Not Used
54
Keypad Access
55
Confirm
56
Force Restore
57
Bell Extend
58
Power Alarm
59
Part Tone
60
Not Used
61
Activity Mon
62
Lockout
63
Banner alerts
64
Set Override
65
Reset Levels
66
Min Pin Size
67
Level Format
68
Line Fail
69
Alert Inds
70
SWDC Set Dly
71
MF BL Enable
72
Max Alm Cause
73
Guard Unset
74
Back-up Link
75
Back-up Timer
6-39
Groups
GX-Series
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available
not available

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-520Gx-48

Table of Contents