Advertisement

RUN BELL WIRES
IN CONDUIT
WIRES MUST BE
RUN IN CONDUIT
TRANSFORMER
GND WIRE (GRN)
NUT (GRN)
AND LOCKWASHER
CABINET DOOR
Mercantile Safe and Vault Listing Guidelines
Follow the guidelines given above for Mercantile Premises listing.
For safe and vault installations, a shock sensor (not supplied) that is listed for protection of sheet metal
enclosures, as well as an additional tamper switch, must be installed on the cabinet backbox to protect
the cabinet from being removed from the wall. These devices must also be wired to the cover tamper on
the PCB. See Figure 2-4 for the location of the PCB terminal block.

Installing the PCB in the Control

To install the circuit board in the cabinet, perform the following steps:
Step
1.
Confirm the Mounting Plate is installed securely in the cabinet.
2.
Place the board flat and secure to the mounting plate with the six accompanying screws. (See
Figure 2-3)
NOTE:
Make sure that the mounting screws are tight.
Use shielded wire or keep wiring away from the microprocessor (center) section of the PC board. Use the
mounting plate brackets on the left and right sidewalls of the cabinet for anchoring field wiring using tie
wraps (Figure 2-3). These steps are important to minimize the risk of panel RF interference with television
reception.
The 7 transistorized outputs on the GX-Series can be configured to open collectors by setting the dip switch
SW3 to the OFF position. Table 2-1 shows which outputs are controlled by which switches.
Note: Output 2 on RIO 0 (relay output) is not affected. This is a form C relay that can switch up to 1 amp at
24 volts DC.
GX-Series Control Panel Installation and Setup Guide
MOUNTING
SCREWS
(3)
PC
BOARD
ON
ON
1 1
2 2 3 3
4 4
5 5
6 6 7 7
8 8
A3 B3
A4
B4
N/O C N/C
PLATE
MOUNTING
SCREWS
(3)
PLUG THESE
KNOCKOUTS
Figure 2-3. Cabinet Attack Resistance Considerations
(SW3)
1
2
3
4
5
6
7
Table 2-1. SW3 Transistorized Output Control
PLUG THIS
KNOCKOUT
DISC PLUGS AND A CARRIAGE BOLT AS SHOWN.
TAMPER
SWITCH
LOCATION
CABINET
KNOCKOUT
TAMPER
SWITCH
LOCATION
HEX NUT AND
WASHER
PLUG THIS
KNOCKOUT
RUN ALL REMAINING
WIRE THROUGH HERE
Action
RIO
Output
0
1
0
3
0
4
1
1
1
2
1
3
1
4
2-3
TO PLUG AN UNUSED KNOCKOUT OPENING,
REMOVE KNOCKOUT AND INSTALL A PAIR OF
DISC PLUGS
(DIMPLES IN DISC
PLUG SHOULD
REGISTER INSIDE
OPENING
KNOCKOUT OPENING)
CARRIAGE BOLT
CABINET SIDE WALL
(OUTSIDE)