1 = Control
Each lighting output can be controlled by setting to 0=OFF, 1=Toggle or 2=Trigger.
If the Control is set to Toggle or Trigger for an output, it will be controllable via the TouchCenter
whose group map contains the output's group. If the Control is set to OFF it cannot be controlled or
viewed by the TouchCenter.
2 = Show Status
The status can be either 0=OFF or 1=ON. When set to ON the light shows the state of the output.
7 = Output Groups
NOTE: The Groups attribute is only available if groups have been enabled on the system (refer to option 63 =
OPTIONS).
The Group attribute allows the output to be assigned to the groups on the system; an output can be
assigned to more than one group. All outputs default to all groups on the system.
On selecting the Output Groups attribute, the groups that the output is currently assigned to are
displayed. Press the relevant number keys to toggle the status of the group and press the ent key; if the
group number is displayed on the top line, then the group is assigned to the output; if a dash (–) appears in
place of the group number, the group has been removed from the output.
The output will activate if triggered by an event in any of the groups assigned to that output, unless output
group status has been programmed.
Multi-group Systems
The GX-520 panel has 32 groups; these are displayed on the keypad in block of eight groups, subdivided into
A, B, C and D:
Use the A> or <B key to select the required group (A1–D8). When the end of a block is reached, the next
block of eight groups is selected; press keys 1–8 to toggle the status of the relevant group in the current block
to the output; press the ent key to accept the selection.
Group Status
This group attribute offers an additional feature that makes the operation of the output conditional on the
set (armed) status of each of the system groups. An output assigned Group Status only activates if the set
(armed) conditions of the programming are met, for example, an Intruder output used to trigger a
communicator can be programmed to activate only if groups 2 and 4 are set (armed) and group 3 is unset
(disarmed).
To assign the Group Status conditions, press the * key when selecting the groups: an arrow (>) is displayed
on the bottom line as well as the current Status. Press the relevant number keys to toggle the status of the
groups and press the ent key to accept the programming. The available group status conditions are:
S = Set (armed) — group must be set (armed) to allow output to activate;
U = Unset (disarmed) — group must be unset (disarmed) to allow output to activate;
– = Set (armed) or unset (disarmed) — output activation is independent of the group status.
GX-Series Control Panel Installation and Setup Guide
Group Block
Physical Groups
A1-8
1-8
B1-8
9-16
C1-8
17-24
D1-8
25-32
Table 6-20. Output Groups
roups
12345678
STATUS >-SUS----
6-67
GX-098-V0