GX-Series Control Panel Installation and Setup Guide
28 Video
This function is identical to the Intruder function, with the exception that the cumulative number of
activations from Video zones, before a full alarm is generated, is programmable. The number of activations
required is determined by the Video parameter (option 51.30); the range is 1–9. The activation count is
incremented when any Video zone in the group activates; the count is reset to zero when the group is unset
(disarmed).
29 Video Exit
The Video Exit function is identical to the Video function, with the exception that the user can activate the
zone during setting (arming) and unsetting (disarming) without incrementing the Video activations count.
The Video output is not activated during setting (arming) and unsetting (disarming).
30 Intruder Delay
The Intruder Delay function is identical to the Intruder function, with the exception that the full alarm
activation can be delayed for up to 50 minutes (0–3000 seconds); this is determined by the Delay Alarm
parameter (option 51.31). The Intruder Delay zone must remain open for the period of the Delay Alarm
parameter; while the zone is open the Entry/Exit Horns activate to remind the user that the Delay Alarm
is counting down. Unsetting (disarming) the system or closing the Intruder Delay zone aborts the alarm
and resets the timer.
If a second Intruder Delay zone opens followed by the first zone closing, the Delay Alarm time continues
to count from the activation of the first zone. The Delay Alarm timer is reset only when all delay type zones
return to the closed state.
31 Log Delay
The Log Delay function operation is identical to the Log function, with the exception that the recording of
the zone activation can be delayed for up to 50 minutes (0–3000 seconds); this is determined by the Delay
Alarm parameter (option 51.31). Closing the Log Delay zone resets the timer and aborts the recording of
the event in the log.
32 Set Log
The Set Log function is identical to the Log function, with the exception that zone activations are only
recorded in the event log during the set (armed) period.
33 Custom A
The Custom A function allows a zone to be assembled. The functionality of the zone; when it activates; the
outputs activated; if it sets (arms) or unsets (disarms) the systems; if it logs, are assigned using menu option
64 = ASSEMBLE ZONE. Once the Custom A zone has been created, it can be assigned to as many zones
as required.
34 Custom B
This function is identical in operation and assembly to Custom A.
35 = Exit Guard
The Exitguard function allows a zone to be used to omit (bypass) other zones on the system. This is useful
for permitting access via doors programmed as 24 Hours or Security.
The Exitguard zone must be the source of a link (refer to option 54 = LINKS); the destination of the
Exitguard link is either a zone address or an output type.
When opened, the Exitguard omits the zone entered as the link destination; an alarm is not activated if the
Exitguard zone is open while a zone that it is omitting is open. If the destination zone is opened while the
Exitguard zone is closed, an alarm activation occurs; opening the Exitguard omits the zone and silences
the output types assigned to the link destination. Closing the Exitguard zone while the destination zone is
still open does not result in an alarm activation; closing the destination zone deactivates the link and
returns the zone to its normal operation.
NOTE: The Exitguard function cannot be used as a link source to activate a link destination output.