3. After doing
the reset(8) command with the "por" option from the XSCF Shell, or forcibly
turn off power by using any of the following methods:
Method 1. Press and hold down the POWER switch on the operator panel of the
main unit for four seconds.
Method 2. Execute the poweroff(8) command from the XSCF Shell.
Q. What kind of processing is executed by XSCF from the time that input power to
the main unit is turned on until the operating system starts?
A. The processing flow before system startup is as follows:
1. The operator turns on input power.
2. XSCF starts.
3. The operator turns on the power to the server.
4. XSCF initializes the hardware.
5. The POST starts and performs an initial diagnosis of hardware.
6. OpenBoot PROM starts.
7. OpenBoot PROM starts the boot process.
8. The operating system starts.
Q. During normal log in to or log out from XSCF, what kind of messages are
displayed on the terminal?
A. The following example shows successful log in to XSCF:
login: jsmith
Password: xxxxxxxx
XSCF>
The following example shows an unsuccessful log in:
login: jsmith
Password: xxxxxxxx
Login incorrect
The following example shows a successful log out from XSCF:
XSCF> exit
logout
D-6
SPARC Enterprise Mx000 Servers XSCF User's Guide • August 2009
Step
2, if the reset operation or the "sync" command fails, execute