Could Not Connect to XSCF Through the Serial Port
Check the connection between the terminal software and the serial port.
■
Check the settings of the terminal software (baud rate is set to 9600 bps, delay is
■
set to 0, etc.). For information about the settings, see "Connecting to XSCF via the
serial port" in
Could Not Connect Using Telnet to XSCF via the XSCF-LAN
Check the LAN cable connection between the XSCF terminal and the server.
■
Check the connection between the terminal software and the telnet port.
■
Use the shownetwork(8) command to check whether the setting for the XSCF-
■
LAN is enabled.
Use the showtelnet(8) command to check whether the setting for telnet is
■
enabled.
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed its
■
maximum number. For information about the maximum number, see
and
If necessary, use the console on the personal computer that is directly connected
■
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings by using the shownetwork(8) command.
Could Not Connect Using SSH to XSCF via the XSCF-LAN
Check the LAN cable connection between the XSCF terminal and the server.
■
Use the shownetwork(8) command to check whether the setting for the XSCF-
■
LAN is enabled.
Use the showssh(8) command to check whether the setting for SSH is enabled.
■
Check whether the entered IP address and port number match their settings.
■
Confirm that the number of connections using telnet/SSH does not exceed limit.
■
For information about the limitation, see
If necessary, use the console on the personal computer that is directly connected
■
to XSCF through the serial port to log in to the XSCF Shell, and check the XSCF-
LAN settings using the shownetwork(8) command.
Check whether the host key has the correct setting. During XSCF Unit
■
replacement, the host key setting is restored to the preset key setting of XSCF.
Check whether the client software has the correct settings.
■
D-2
SPARC Enterprise Mx000 Servers XSCF User's Guide • August 2009
Chapter
3.
Chapter
3.
Chapter
3.
Chapter 2
Need help?
Do you have a question about the Sun SPARC Enterprise M3000 and is the answer not in the manual?