To check whether a fault occurred if a message is output to the domain console
■
and XSCF console. (See
To check whether the information is fault information if it was reported to the
■
previously registered email address.
To check whether the information is fault information if TRAP occurred in the
■
SNMP manager.
Using the showlogs(8) Command to Confirm a Fault
1. Specify the error option on the XSCF Shell and perform the showlogs(8)
command to reference the XSCF error log.
XSCF> showlogs error
Date: Mar 30 15:45:31 JST 2005
Status: Warning
FRU: PSU#1,PSU#2
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
Date: Mar 30 17:45:31 JST 2005
Status: Alarm
FRU: PSU#1,PSU#2,*
Msg: ACFAIL occurred (ACS=3)(FEP type = A1)
(The layout of the command example is subject to change without previous notice
for functional improvement.)
In the example above, the following items are displayed:
Time at which each problem was logged (Date). This date is indicated in local
■
time.
DIAGCODE that the field engineer and authorized service personnel use for
■
troubleshooting (Code). The user is requested to inform the field engineer and
authorized service personnel of this Code. This is useful in settling the problem at
an early stage.
Fault level of the component (Status). One of the following items is displayed:
■
Alarm:
Warning:
Time at which each problem occurred (Occurred). This is indicated in local time.
■
Replacement component (FRU) that is probably faulty. A comma (,) separates two
■
suspect components displayed. For additional suspect components, an "*"
(asterisk) is displayed after the comma (,). Each component is displayed
B-2
SPARC Enterprise Mx000 Servers XSCF User's Guide • August 2009
Appendix
A.)
Code: 00112233-44556677-8899aabbcceeff00
Occurred: Mar 30 15:45:26.000 JST 2005
Code: 00112233-44556677-8899aabbcceeff00
Occurred: Mar 30 15:45:26.000 JST 2005
The relevant component failed.
Some subcomponents in the relevant component failed or degraded.
Need help?
Do you have a question about the Sun SPARC Enterprise M3000 and is the answer not in the manual?