4. Use the testsb(8) command to check the PSB, then check the results by using
the showboards(8) command.
XSCF> testsb 0
Initial diagnosis is about to start. Continue? [y|n] : y
Initial diagnosis is executing.
Initial diagnosis has completed.
XSB
---- ------- --------
00-0 Passed
00-1 Passed
00-2 Passed
00-3 Passed
XSCF> showboards -va
XSB
---- - -------- ----------- ---- ---- ---- -------
00-0
00-1
00-2
00-3
01-0
02-0
2.2.13

Domain Mode Configuration

Domain mode configuration is used to specify the initial hardware diagnostic level,
enables or disables break signal suppression, enables or disables host watchdog,
enables or disables automatic boot and CPU operational mode for the specified
domain.
You may want to suppress some functions for a domain during system operation or
maintenance. For example, during system maintenance, you may not want to use
automatic boot (enable automatic boot suppression), suppress a break signal from
the console (enable break signal suppression), or suppress a panic during a Host
watchdog reset.
In the M3000 server, CPU operational mode cannot be configured.
Test
Fault
Normal
Normal
Normal
Normal
R DID(LSB) Assignment
SP
Unavailable n
SP
Unavailable n
SP
Unavailable n
SP
Unavailable n
SP
Unavailable n
SP
Unavailable n
Pwr
Conn Conf Test
n
n
Passed
n
n
Passed
n
n
Passed
n
n
Passed
n
n
Unknown
n
n
Unknown
Chapter 2
Fault
COD
-------- ----
Normal
n
Normal
n
Normal
n
Normal
n
Normal
n
Normal
n
Setting Up XSCF 2-125