Eclipse 8/ 32 Series - Installation Manual

1. GENERAL INFORMATION

The ECLIPSE series Alarm control panels are designed and tested in compliance with electromagnetic compatibility
(EMC) standards. The ECLIPSE 32 alarm control panel covers the requirements of GRADE 2.
The following recommendations need to be observed for the proper performance of the alarm station:
 Ensure the alarm system is properly earthed (grounded).
 Insulate the high and low voltage cables and use different input openings on the box.
 Avoid any loops of connecting wires within the very box and in their passage over or under the printed circuit
boarding.
 Additional relays MUST NOT be placed in the Eclipse 8/32 Alarm control panel box as these may generate
electromagnetic interference when switched.
- Use only relays with good insulation between contacts and the winding.
- Relays, connected to outputs with an open commutator, must be designed to accommodate a 12 V DC
driving voltage and an impedance at the winding greater than 400Ω.
 The cable connecting the control panel and the keyboard is quadruple.
It is strongly recommended not to: use this cable to make other connections - connect to a telephone line, Flash-
lamps control signals, sirens or relays.
 Avoid channels or cable forms that contain high voltage cables when placing the connecting shielded cables. This
is very important in cases where such cables are being used to power electric motors, fluorescent lamps or triple-
phase voltage. Where the above is not possible, use only shielded cables, where the shield is grounded only in the
alarm system box.
Technical Features:
Feature
Zones (on board)
Max. Zones (expanded)
Areas
4 x 100mA Outputs
1 x 1A Monitored Output
Max. Outputs (expanded)
User Codes
Schedules
LOG Events
BUS Devices
Programming
Arming modes
Digital communicator
Voice Dialer (option)
Remote programming
Technical Specifications:
Specification
Mains Power Supply
Mains Transformer
Back-up Power Supply
Accumulator charger
Consumption
Enclosure
Dimensions, mm
Operation temperature
Relative humidity
Weight, kg
ECLIPSE 8
6
8
1
-
5
8
-
256
2
Address, Operation, Text menus; ProsTE software
Full, Stay, Sleep
 (2 tel. numbers)
 (8 tel. numbers)
-
ECLIPSE 8
230 VAC ±10%, fuse 0.63A
17 VAC / 17 VA
1 x Accumulator 12 V / 7 Ah
13.8V, resettable fuse 0.75А
100 mA (for control panel)
ABS plastic box, white
290 x 240 x 80
from -10°C to +60°C
95%
1.40
ECLIPSE 32
8
32
8
32
64
1024
31
 (4 tel. numbers)
 (8 tel. numbers)
ECLIPSE 32
15-26 VAC / 50 VA
335 x 290 x 105
from 0°C to 50°C
95%
2.30
6

Hide quick links: