Assembly
Tools:
❒ Allen wrench, size 4
Steps:
1. Hold the front lights mounting kit in place on the chassis.
2. Attach with two Allen head screws.
3. Feed the connection cable to the plug and connect.
Figure 44 Front-mounted lighting
Replacing defective lamps
Tools:
❒ Allen wrench, size 3
❒ Flathead screwdriver, small
Steps:
1. Fold the halogen lamp with cover forward by pressing the black locking lever on the bottom
of the lamp.
2. Pull the retaining ring back.
3. Pull the halogen lamp back, remove it and replace if required.
4. Properly reassemble all components upon completion of the work.
INFORMATION
During installation, ensure that the notch on the halogen lamp socket is positioned correctly and
engages.