Instrument Cluster With Mechanical Transmission Range Indicator - Chrysler 1998 Voyager Service Manual

Table of Contents

Advertisement

8E - 24
INSTRUMENT PANEL AND SYSTEMS
REMOVAL AND INSTALLATION (Continued)
Fig. 22 Instrument Panel –Electronic Transmission
Range Indicator
(2) Connect wire connector into back of instrument
cluster.
(3) Position instrument cluster in instrument
panel.
(4) Install instrument cluster mounting screws to
instrument panel.
(5) Install instrument cluster bezel.
INSTRUMENT CLUSTER WITH MECHANICAL
TRANSMISSION RANGE INDICATOR
REMOVAL
(1) Remove the lower steering column cover.
(2) Remove the metal knee blocker panel.
(3) Disconnect the transmission range indicator
cable end from shift lever by flexing the HOOP on
the transmission shift cable rearward and slip the
indicator cable loop off the lever pin (Fig. 23).
(4) Disconnect the clip holding the indicator cable
to the steering column/transmission shift cable
bracket.
(5) Remove the instrument cluster bezel.
(6) Rotate top of the cluster rearward.
(7) Disconnect the wire connector from back of the
instrument cluster.
(8) Remove the instrument cluster carefully while
guiding the range indicator cable and guide tube
through the opening to avoid any damage (Fig. 24).
INSTALLATION
(1) Verify the free travel of the range indicator
cable from P to 1 by gently pulling on the cable and
relaxing the cable. DO NOT SNAP THE CABLE
ONCE IT IS PULLED.
(2) Position the instrument cluster in instrument
panel and route the indicator cable and guide tube
through the opening in the instrument panel. Posi-
Fig. 23 Range Indicator
Fig. 24 Removing and Installing Cluster
tion the cluster by leading the bottom in first, con-
nect the wire connector, and rotate upward.
(3) Install the screws to hold the instrument clus-
ter to the instrument panel.
(4) Install the instrument cluster bezel.
(5) Connect the clip to hold the indicator cable to
steering column/transmission shift cable bracket. The
indicator cable and guide tube should BOW towards
the passenger side of the vehicle (Fig. 25).
(6) Connect indicator cable loop end to shift lever
by flexing the hoop on the transmission shift cable
rearward, then slip the indicator cable loop over the
shift lever pin and into the groove.
(7) Assuming the transmission shift system is
properly adjusted, place the shift lever in neutral N
position.
NOTE: The
parking
engaged for safety purposes.
brake
should
have
NS
been

Hide quick links: