Chrysler 1998 Voyager Service Manual page 573

Table of Contents

Advertisement

NS/GS
SERVICE PROCEDURES (Continued)
(5) Push the two ends of wire together until the
strands of wire are close to the insulation (example
2) (Fig. 10)
(6) Twist the wires together (example 3) (Fig. 10)
(7) Solder the connection together using rosin core
type solder only. Do not use acid core solder.
(8) Center the heat shrink tubing over the joint,
and heat using a heat gun. Heat the joint until the
tubing is tightly sealed and sealant comes out of both
ends of the tubing.
(9) Secure the wire to the existing ones to prevent
chafing or damage to the insulation
(10) Connect battery and test all affected systems.
Fig. 10 Wire Repair
TERMINAL/CONNECTOR REPAIR-MOLEX
CONNECTORS
(1) Disconnect battery.
(2) Disconnect the connector from its mating half/
component.
(3) Insert the terminal releasing special tool 6742
into the terminal end of the connector (Fig. 11).
(4) Using special tool 6742 release the locking fin-
gers on the terminal (Fig. 12).
(5) Pull on the wire to remove it from the connec-
tor.
(6) Repair or replace the connector or terminal, as
necessary.
CONNECTOR REPLACEMENT
(1) Disconnect battery.
(2) Disconnect the connector that is to be repaired
from its mating half/component
8W-01 GENERAL INFORMATION
required (Fig. 13)
the terminal using the proper pick from special tool
Fig. 11 Molex Connector Repair
Fig. 12 Using Special Tool 6742
(3) Remove
the
connector
Fig. 13 Connector Locking Wedge
(4) Position the connector locking finger away from
8W - 01 - 11
locking
wedge,