8.10.4 Replacing the calf plate on the centre-mounted legrest (electric & manual)
Requirements:
● 1/64" Allen key
A manual legrest can be seen in the illustration. The method of fixation to the seat is almost
identical with both legrests.
Uninstalling the calf plate:
If possible, raise the lifter to the highest position.
If possible, tip the wheelchair with the tilt module as far backwards as it will go.
Switch the electronic control system off.
Use the 1/64" Allen key to loosen and remove both screws (2).
Remove the calf plate (1).
Installing the calf plate:
Assemble the parts in reverse order.
Using the different adjustment holes (3) in the calf plate and in the calf plate brackets, the calf
plates can be mounted at different heights and widths. This must be adjusted to fit the needs
of the user.