Testing the electro-mechanical parking brake

Note
This test should only be carried out on mobility aids with conventional motor/transmission units.
Requirements:
● Phillips screwdriver size 2
● digital multimeter with resistance measurement
Remove the rear panel as described in Chapter 8.1.2.
Pull the motor plug (3) out of the electronic module.
Connect the digital multimeter to the adjacent central motor plug contacts (3) and measure the
resistance between the contacts.
If there is a defect, replace the motor and send it to Invacare® Service for inspection or repair.
Note
A resistance of between 40 and 80 ohms indicates an intact brake.
A resistance of 0 ohms or a very high resistance (mega-ohms or infinity) indicates a short-circuit,
a bad connection or a defective brake.