8.6.4

Replacing the operating hours counter / connecting cable

Requirements:
● 10 mm socket wrench
The operating hours counter is located on the rear cover (2).
Removing the operating hours counter:
Switch the electronic system of the wheelchair off.
Remove the rear cover as described in chapter 8.1.2.2.
Loosen and remove the nut (5) including the locking washer (4) using a 10 mm socket wrench.
Pull the mounting bracket (2) off of the threaded rod (3).
Remove the retaining frame (6).
Pull the operating hours counter forwards out of the rear cover.
Disconnect the two plugs of the cable (not shown in the illustration) from the pins (-) & (+).