Invacare
- TDX-SP / TDX-SP N
●
Undo the two Allen screws (3) on both sides of the seat with a 6 mm Allen key.
●
Remove the screws and the washers.
●
Lift the tilt module (1) off the battery case.
●
If one of the tilt mountings (2) needs to be replaced:
- undo the four bolts (4) on the appropriate side of the seat using a ½" socket spanner.
- remove the tilt mounting.
Refitting the tilt module:
●
Refit the tilt module in the reverse sequence.
●
Tighten the connecting bolts between the tilt mounting and the battery case to 18 Nm.
●
When routing the cable, ensure that it has been placed in the cable clamps so that it cannot be
crushed or damaged in any way at any seat setting.
●
Refit the batteries including battery supports as described in Chapters 8.2.2/8.2.3 and 8.2.1.
WARNING: Danger of crushing!
The seat is very heavy. Injury hazard to hands and feet!
● You should seek help from a second person.
●
Refit the seat.
●
Adjust the anti-tip system as described in Chapter 8.16.5.
SERVICE MANUAL