SERVICE MANUAL
8.19

Drive unit

8.19.1 Replacing the motor/transmission unit (Standard motor)

WARNING: Danger of crushing!
The wheelchair is very heavy. Danger of injury to the hands and feet!
● Let a second person help you.
Danger of injury due to uncontrolled movement of the wheelchair!
● Switch the vehicle's power system off (ON-/OFF key).
● Engage the drive motors.
● Secure the vehicle against rolling away by placing wedges under the wheels.
ATTENTION: Danger of crushing!
The motor gearbox unit is extremely heavy. Injury hazards to hands!
● Please note the high weight
Requirements:
● 5/8" Allen key
● 7/8" Allen key
● 5/16" Allen key
● Phillips screwdriver size 2
● 1/2" socket spanner
● 1/4" socket spanner
● 5/16" socket spanner
● torque wrench 5 - 25 Nm (or similar)
● torque wrench 10 - 80 Nm (or similar)
● two long wooden blocks, min. 14 x 14 x 30 cm
Removing the motor/transmission unit:
Remove the drive wheel as described in Chapter 8.13.1.
Remove the wheel hub as described in Chapter 8.13.3.
Remove the bottom walking beam as described in Chapter 8.17.
Remove the top walking beam as described in Chapter 8.18.
Loosen and remove the three nuts (2) with a 5/16" socket spanner.
Remove the washers (3).
Take note of the optional wheel lock (6) if fitted.