8.16.4 Replacing the setting screw

WARNING: Danger of crushing!
The mobility device is very heavy. Injury hazard to hands and feet!
● You should seek help from a second person.
Injury hazard caused by uncontrolled movement of the mobility device!
● Switch the power supply off (ON/OFF key).
● Engage the drive.
● Before raising the vehicle, secure the wheels by blocking them with wedges.
Requirements:
● 1/4" socket spanner
● two long wooden blocks, min. 14 x 14 x 30 cm
● M8 washer
Note
Invacare® recommends always replacing both setting screws simultaneously in order to ensure
that the mobility aid works perfectly.
Removing the setting screw:
Lift the mobility aid up on one side and get a second person to place a wooden block around
14 cm high underneath it so that the wheels are suspended freely.
Repeat the same procedure on the other side of the mobility aid.
Remove both the anti-tip system protective caps.
The protective caps on the anti-tip system will either be held using a screw or a cable tie
depending on the mobility aid's date of manufacture.
Undo the two bolts (2) with a 1/4" socket spanner, and remove the bolts together with the
nylon washers (3).