8.16.4 Replacing the setting screw
WARNING: Danger of crushing!
The mobility device is very heavy. Injury hazard to hands and feet!
● You should seek help from a second person.
Injury hazard caused by uncontrolled movement of the mobility device!
● Switch the power supply off (ON/OFF key).
● Engage the drive.
● Before raising the vehicle, secure the wheels by blocking them with wedges.
Requirements:
● 1/4" socket spanner
● two long wooden blocks, min. 14 x 14 x 30 cm
● M8 washer
Note
Invacare® recommends always replacing both setting screws simultaneously in order to ensure
that the mobility aid works perfectly.
Removing the setting screw:
●
Lift the mobility aid up on one side and get a second person to place a wooden block around
14 cm high underneath it so that the wheels are suspended freely.
●
Repeat the same procedure on the other side of the mobility aid.
●
Remove both the anti-tip system protective caps.
The protective caps on the anti-tip system will either be held using a screw or a cable tie
depending on the mobility aid's date of manufacture.
●
Undo the two bolts (2) with a 1/4" socket spanner, and remove the bolts together with the
nylon washers (3).
SERVICE MANUAL
123