Chapter
4
Parallel Interface Menu

IEEE 1284

The IEEE 1284 interface is configured using the following configuration
options.
IEEE 1284
(from page 136)
Buffer Size in
Kbytes
16*
(1-16)
Buffer Size in Kbytes
This option configures the amount of memory allocated for the IEEE 1284
parallel port buffer. You can specify between 1 and 16 Kbytes, in 1-Kbyte
increments.
16 (the default)
1 – 16
Auto Trickle
Auto Trickle is used to prevent a host computer from timing out because the
parallel interface was busy for too long. When Auto Trickle is enabled and the
printer's buffers are almost full, the printer will begin to trickle data in (at the
rate set in the Trickle Time menu) until the buffers start to empty out.
144
Auto
Trickle
Trickle
Time
Disable*
1/4 sec*
Enable
1/2 sec
1 sec
2 sec
4 sec
8 sec
16 sec
OFF
* = Factory Default
To cycle through the menus and its
options, press MENU then:
Scroll/
OR
Micro
To enter a menu or select menu options,
press ENTER.
To return to a previous menu level,
press RETURN.
To exit the configuration menus
and return to READY, press START.