Lead-In Characters
The Lead-In Character commands must have a start and end code. Set 1 is
the factory default. Three sets (each containing a start and end code) are
available:
Set 1: start code = <% (the default)
end code = >
Set 2: start code =
end code = $
Set 3: start code = _%
end code = _
User Defined
User Defined Codes
Start Code 2: 5F (the default)
Start Code 1: 5F (the default)
Stop Code: 5B (the default)
The codes have a range of x'40' - x'FF'.
Alternate Set 80 - 9F
This selection determines if ASCII codes 80 hex through 9F hex will be used
as control codes or printed as standard printable characters.
Printable (the default). Prints the alternate set as standard characters
Control Code. Selects the alternate set to be used as printer control
codes.
Undefined Char Report
UNDEFINED CHARACTER REPORTING allows overriding of the host
setting of the SGEA (Set Graphic Error Action) command. For more
information about the SGEA command, refer to the InfoPrint 6500 Line Matrix
Printers: CTA Programmer's Reference Manual.
Enable (the default). The host setting for the SGEA and is used by the
printer. If the SGEA command is requested to stop on graphic errors, the
printer will stop when a graphic error is detected.
Disable. Ignores the SGEA command from the host. The printer does not
stop when an error is detected; instead, it substitutes the character
selected in the "UNDEFINED CHARACTER SUBSTITUTION" menu
entry.