Fault Message
062 EXHAUST FAN CHECK
SEE USERS MANUAL
065 HAMMER FAN CHECK*
SEE USERS MANUAL
069 DATA CLEARED
080 POWER SUPPLY HOT
081 POWER VOLT CHECK*
SEE USERS MANUAL
082 POWER 8.5V CHECK*
SEE USERS MANUAL
Table 9: Fault Messages
Operator
Explanation
Correctable?
Yes
Sensors cannot
detect current in fan
circuit.
Yes
Sensors cannot
detect current in fan
circuit.
N/A
Appears when data is
cleared out of printer
after Cancel key has
been pressed.
No
Power supply
temerature is elevated
beyond normal
threshold.
No
Power supply voltage
failure.
No
Internal power failure.
Fault Messages
Fault Correction Procedure
Solution
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your
InfoPrint service
representative. NOTE:
This message should not
appear on a Pedestal
model. If this message
does appear, contact your
InfoPrint Service
Representative.
Power off the printer.
Check for obstruction of
vents and fan airway;
remove any obstructions.
Check for items beneath
the printer blocking cabinet
vents. Power back on the
printer. If this message
reoccurs, contact your
InfoPrint service
representative.
No action required.
Contact your InfoPrint
service representative.
Contact your InfoPrint
service representative.
Contact your InfoPrint
service representative.