Fault Message
CRTG NOT SETx
Re-install RBN
DIAGNOSTIC PASSED
DO NOT POWER OFF
DOWNLOADING %%
DP FIFO BUSY*
DRIVER CIRCUIT BAD
SEE USERS MANUAL
E00 EXE @ ADDR0
See User Manual
Table 9: Fault Messages
Operator
Explanation
Correctable?
Yes
The ribbon cartridge
is not properly
positioned.
N/A
Status message: the
printer passed its
memory and
hardware initialization
tests.
N/A
Status message: the
new emulation
program is loading
into printer RAM.
XX% indicates how
much of the program
has loaded.
No
There is a timing
problem in the Engine
Controller firmware.
No
The hammer coil
count test failed.
Yes
An illegal or
unsupported
instruction was
attempted in the
application program.
Fault Messages
Fault Correction Procedure
Solution
1. Make sure a ribbon
cartridge is installed in
the printer.
2. Make sure the ribbon
cartridge is seated
properly.
3. Remove and replace
the cartridge if
necessary.
4. Contact your InfoPrint
service representative.
No action required.
No action required.
Contact your InfoPrint
service representative.
Contact your InfoPrint
service representative.
1. Cycle Power. Run the
print job again. If the
message appears,
load the latest
emulation software.
2. Cycle power. Run the
print job again. If the
message appears,
record the display
message and send it to
your next higher
support facility.
265