TOF Act at Prime Signal
TOF (Top–of–Form) ACTION AT PRIME SIGNAL determines whether or not
a form feed is performed before a warm start when the prime signal is
asserted from the host. This setting is only used if PRIME SIGNAL parameter
is enabled.
Form Feed At Reset (the default)
No Form Feed At Reset.
Buffer Size in Kbytes
Configures the amount of memory allocated for the PC Parallel port buffer.
You can specify between 1 and 16 Kbytes, in 1-Kbyte increments.
16K (the default)
1 – 16K
Auto Trickle
Auto Trickle is used to prevent a host computer from timing out because the
parallel interface was busy for too long. When Auto Trickle is enabled and the
printer's buffers are almost full, the printer will begin to trickle data in (at the
rate set in the Trickle Time menu) until the buffers start to empty out.
Trickle Time
This functionality prevents an attached host from timing out. To support this
feature, the port has to be able to accept data from the host and store it for
future use. The selected value is the time that the printer waits before getting
the next byte of data from the host. Set the value to be less than the host time
out value. If the value is too much shorter, the printer fills up its buffer too fast.
140
1/4 Sec (the default)
1/2 Sec
1 Sec
2 Sec
4 Sec
8 Sec
16 Sec
OFF