Operation Manual – HWPing
H3C S5600 Series Ethernet Switches
Configure the destination
port
Configure the source IP
address
Configure the source port
Configure the number of
probes per test
Configure the maximum
number of history records
that can be saved
Configure the data packet
size
Configure the automatic
test interval
Configure the probe
timeout time
To do...
destination-port
port-number
source-ip ip-address
source-port port-number
count times
history-records number
datasize size
frequency interval
timeout time
Use the command...
1-17
Chapter 1 HWPing Configuration
Remarks
Required
in
Udpprivate test
A Udppublic test is a
UDP connection test
on port 7. Use the
hwping-server
udpecho ip-address 7
command
on
server to configure the
listening service port;
otherwise the test will
fail. No port number
needs to be configured
on
the
client;
destination
number configured on
the client will not take
effect.
By
default,
destination
number is configured.
Optional
By default, no source IP
address is configured.
Optional
By default, no source port
is specified.
Optional
By default, one probe is
made per test.
Optional
By default, the maximum
number is 50.
Optional
By default, the data
packet size is 100 bytes.
Optional
By default, the automatic
test interval is zero
seconds, indicating no
automatic test will be
made.
Optional
By default, a probe times
out in three seconds.
a
the
any
port
no
port

Advertisement