H3C LS-S5600-26C-OVS Installation Manual
H3C LS-S5600-26C-OVS Installation Manual

H3C LS-S5600-26C-OVS Installation Manual

S5600 series ethernet switches
Table of Contents

Advertisement

Quick Links

H3C S5600 Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-08045W-20071218-C-1.04

Advertisement

Table of Contents
loading

Summary of Contents for H3C LS-S5600-26C-OVS

  • Page 1 H3C S5600 Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-08045W-20071218-C-1.04...
  • Page 2 Copyright © 2006-2007, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd. Trademarks H3C, , Aolynk,...
  • Page 3: About This Manual

    About This Manual Related Documentation In addition to this manual, each H3C S5600 Series Ethernet Switches documentation set includes the following: Manual Description H3C S5600 Series Ethernet Switches It is used for assisting the users in data Operation Manual configurations and typical applications. H3C S5600 Series Ethernet Switches It is used for assisting the users in using Command Manual...
  • Page 4 Conventions The manual uses the following conventions: I. GUI conventions Convention Description Button names are inside angle brackets. For example, click < > <OK>. Window names, menu items, data table and field names are inside square brackets. For example, pop up the [New User] window.
  • Page 5: Table Of Contents

    Installation Manual H3C S5600 Series Ethernet Switches Table of Contents Table of Contents Chapter 1 Product Overview ......................1-1 1.1 Overview ..........................1-1 1.2 S5600-26C/S5600-26C-PWR/S5600-26F Ethernet Switch ..........1-2 1.2.1 Front Panel......................1-2 1.2.2 Rear Panel ......................1-10 1.3 S5600-50C/S5600-50C-PWR Ethernet Switch ............... 1-11 1.3.1 Front Panel......................
  • Page 6 Installation Manual H3C S5600 Series Ethernet Switches Table of Contents 3.5.1 Console Cable....................... 3-16 3.5.2 Connecting the Console Cable ................3-16 3.6 Installing/Removing the Stack Cable ................3-17 3.6.1 Stack Cable ......................3-17 3.6.2 Installing the Stack Cable..................3-17 3.6.3 Removing the Stack Cable..................3-18 3.7 Installing/Removing the Optional Interface Module ............
  • Page 7: Chapter 1 Product Overview

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Chapter 1 Product Overview 1.1 Overview H3C S5600 Series Ethernet Switches are high-performance, high-density, easy-to-install, NMS-manageable intelligent Ethernet switches which support wire-speed Layer2/3 switching. Table 1-1 lists the models of H3C S5600 Series Ethernet Switches. Table 1-1 Models of H3C S5600 Series Ethernet Switches Number of Number of...
  • Page 8: S5600-26C/S5600-26C-Pwr/S5600-26F Ethernet Switch

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Note: The electrical ports of S5600-26C-PWR/S5600-50C-PWR are capable of supplying -48 VDC power to remote PDs (powered devices, such as S2016C, S2008B, S2016B, S2016-EI, and so on). The S5600-26C-PWR/S5600-50C-PWR adopts PoE power module, which provides AC/DC power to PD devices.
  • Page 9 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview The S5600-26F provides 24 x 1000 Mbps SFP optical ports, one Console port, and four 1000 Mbps RJ-45 Combo ports on its front panel. Each SFP port and the corresponding 10/100/1000M Ethernet port form a Combo port.
  • Page 10 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Table 1-3 LEDs on the S5600-26C/S5600-26C-PWR Mark Status Description port status LEDs Speed Solid green showing the speed of each port. The port LEDs are showing the Mode LED Mode Duplex Solid yellow...
  • Page 11 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Mark Status Description The module is seated and Solid green operates normally. Module Module The module fails or is not (MOD) Blinking yellow supported. No module is installed. The POST ID of the in-process POST Blinking test is displayed:...
  • Page 12 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Mark Status Description The port is operating at 1000 Mbps. The LED blinks quickly Green when the port is receiving or sending data. The port is operating at 10/100 Mbps.
  • Page 13 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Mark Status Description The port is operating at 1000 Mbps. The LED blinks quickly Green when the port is receiving or sending data. Speed mode Blinking yellow (3 The port fails the POST. The port is not connected.
  • Page 14 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Mark Status Description The device is in the ring fabric status; the LED blinks quickly Green when the fabric port is receiving or sending data. The device is in the daisy chain fabric status;...
  • Page 15 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Mark Status Description The port is operating at 1000 Mbps. The LED blinks quickly Green when the port is receiving or sending data. The port is operating at 10/100 Mbps.
  • Page 16: Rear Panel

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Item Description Baud rate 9600 bps (default), auto-negotiation is supported Connection to an ASCII terminal Connection to the serial port of a local terminal (a PC for Services example) or a remote terminal (through a pair of modems) running terminal emulation software 1.2.2 Rear Panel I.
  • Page 17: S5600-50C/S5600-50C-Pwr Ethernet Switch

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Table 1-6 Fabric port LEDs Mark Status Indicate Solid green The fabric port is properly connected. Fabric Blinking The fabric port is properly connected and UP(DOWN) port LED green the port is receiving or sending data.
  • Page 18: Rear Panel

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview II. LEDs The S5600-50C/S5600-50C-PWR provides one power LED, RPS LED, fabric LED, module LED, mode LED, 7-segment digitron display, 1000 Mbps SFP port status LED, and auto-negotiation Ethernet port status LED on its front panel. The meaning of each LED is shown in Table 1-3 III.
  • Page 19: Power System

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview 1.4 Power system AC power input range Rated voltage: 100 to 240 VAC; 50/60 Hz Max. voltage range: 90 to 264 VAC; 50/60 Hz DC power input range Rated voltage: –48 to–60 V Max.
  • Page 20: Attributes Of 1000 Mbps Sfp Port

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Table 1-8 S5600 Ethernet switches cooling system Model S5600-50C S5600-26C-PWR Two fans are for the device Two fans are for the device and Cooling system and two are for the power four are for the power supply supply module.
  • Page 21: Expansion Module

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview 1.7 Expansion Module The S5600 Series Ethernet switches provide one expansion module slot on the rear panel. The expansion mode that can be used in this slot includes 8-port 1000 Mbps SFP module, 1-port 10 Gbps XENPAK module, and 2-port 10 Gbps XFP module.
  • Page 22 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Figure 1-7 RJ-45 connector Table 1-11 Pinouts of the RJ-45 GE port 1000Base-TX Signal Function MX_0+ Data transmit/receive MX_0- Data transmit/receive MX_1+ Data transmit/receive MX_2+ Data transmit/receive MX_2- Data transmit/receive MX_1- Data transmit/receive MX_3+...
  • Page 23 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview Table 1-12 XFP optical port module supported by 2-port 10 Gbps XFP module Type Model XFP-SX-MM850 XFP optical module XFP-LX-SM1310 XFP-LH40-SM1550-F1 Note: The switch does not support the 10GBase-ER-XFP module with -5.2 V power supply.
  • Page 24: S5600 Series Technical Specifications

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview This module can also provide a 10 Gbps electrical port. When using this port, you must select the CX4 connector, and the InfiniBand cable with the transmission distance of 15 m (49.2 ft). Note: For specifications of SFP modules, refer to H3C Low End Series Ethernet Switches Pluggable Module Manual.
  • Page 25 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview S5600- S5600-26C S5600- S5600- Item S5600-26F -PWR 50C-PWR PSL130-AD: 130 W system output, AC/DC input PSL480-AD24P: 24-port PoE power module, 180 W system output + 300 W PoE output (AC input); 180 W system output + 370 W PoE output (DC input) Power module...
  • Page 26 Installation Manual H3C S5600 Series Ethernet Switches Chapter 1 Product Overview S5600- S5600-26C S5600- S5600- Item S5600-26F -PWR 50C-PWR Two fans fans are are for Two fans Four fans Two fans for the are for the are for the are for the device device device and...
  • Page 27: Chapter 2 Preparing For Installation

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 2 Preparing for Installation Chapter 2 Preparing for Installation 2.1 Safety Precautions To avoid any device impairment and bodily injury caused by improper use, observe these rules: Before cleaning the switch, unplug the power plug of the switch first. Do not clean the switch with wet cloth or liquid.
  • Page 28: Cleanness

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 2 Preparing for Installation aging of insulation materials and can thus significantly lower reliability and service life of your switch. For the temperature and humidity requirements of different models, refer to section 1.8 S5600 Series Technical Specifications.
  • Page 29: Laser Safety

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 2 Preparing for Installation For the AC power supply that adopts TN system, use a monophase three-line power socket with Protection Earth (PE) to effectively filter interference from the power grid. Keep the device far from radio transmitting stations, radar stations, and high-frequency devices.
  • Page 30: Chapter 3 Installing The Switch

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Chapter 3 Installing the Switch Caution: When you ask your sales agent to maintain the switch, you must ensure that the dismantlement-preventive seal on a mounting screw of the switch chassis is intact. If you want to open the chassis, you should contact the agent for permission.
  • Page 31: Introduction To Guide Rail

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch (1): Screw hole used to fix the mounting ear to the cabinet (Use one M6 screw) (2): Screw hole used to fix the switch to the mounting ear Figure 3-1 Appearance of a front mounting ear Figure 3-2 shows the appearance of a rear mounting ear.
  • Page 32: Use Front Mounting Ears And A Tray

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Slotted hole 1 Cooling hole Slotted hole 2 Slotted hole 1: Used to fix the guide rail to the rear bracket. You can adjust the screw hole position according to the position of the switch. Cooling hole: Used for heat dissipation between switch and cabinet Slotted hole 2: Used to fix the guide rail to the front bracket Figure 3-3 Appearance of a guide rail...
  • Page 33: Use Front And Rear Mounting Ears

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Front square-holed bracket Front square-holed bracket Front mounting ear Front mounting ear Front panel Front panel Front Front mounting ear mounting ear Figure 3-5 Fix front mounting ears and a tray 3.1.4 Use front and rear mounting ears Follow these steps to install a switch into a 19-inch standard cabinet: Wear an ESD-preventive wrist strap to check the grounding and stability of the...
  • Page 34 Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Note: There are three positions to mount a load-bearing screw on both sides of a switch. You should select a proper position according to the actual requirements. The rear mounting ears tightly contacted with the load-bearing screws can support the switch.
  • Page 35 Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Rear mounting ear Screw 2 Front square-holed bracket Rear square-holed bracket Rear panel Front mounting ear Screw 1: Used to bear the weight Screw 2: Used to fix rear mounting ears to rear brackets Figure 3-8 Fix front and rear mounting ears After the switch is pushed into the cabinet, ensure that the upper edge of rear mounting ears is tightly contacted with the load-bearing screw, as shown in Figure 3-9.
  • Page 36: Use Front Mounting Ears And Guide Rails

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Screw 1 Rear mounting ear Front panel Front mounting ear Front square-holed bracket Screw 1: Load-bearing screw Figure 3-10 Effect diagram of front and rear mounting ear installation (2) 3.1.5 Use front mounting ears and guide rails Follow these steps to install a switch into a 19-inch standard cabinet Wear an ESD-preventive wrist strap to check the grounding and stability of the...
  • Page 37 Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Figure 3-12 Install guide rails Hold the two sides of the switch and slide it gently along the guide rails into the cabinet until it is located in a proper position, as shown in Figure 3-13. Ensure that the bottom side of the guide rails and the switch are in close contact.
  • Page 38: Mounting The Switch On A Tabletop/Workbench

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Guide Rear panel rail Figure 3-14 Effect diagram of front mounting ear and guide rail installation Note: Ensure a clearance of 1U (44.45 mm, namely, 1.75 inches) between devices for the purpose of heat dissipation.
  • Page 39: Installing/Removing The Power Module

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch 3.3 Installing/Removing the Power Module Caution: To avoid bodily injury, do not touch any bare conducting wire, screw, and the part which is labeled danger voltage. 3.3.1 Installing the Power Module The power module of the S5600 series is swappable.
  • Page 40: Connecting The Power Cord And The Ground Wire

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Caution: When you use the Phillips screwdriver or power screwdriver to fasten captive screws at both sides of the module, make sure the captive force moment is not larger than 0.4 N•m.
  • Page 41: Connecting The Dc-Input Power Cord

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch 3.4.2 Connecting the DC-Input Power Cord RTN: -48V working ground -48_-60V: -48_-60V NULL: reserved Figure 3-16 DC-input power connector (partial) Step 1: Connect one end of the chassis ground wire to the grounding screw on the rear of the chassis and the other end to the ground as near as possible.
  • Page 42: Connecting The Ground Wire

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Connector Connector component component Screw 2 Screw 2 Screw 1 Screw 1 Cabinet Cabinet Figure 3-18 Fix RPS connector to the cabinet Step 3: After installing connector component, directly insert the component into DC-input socket on the cabinet, and then fix the screws 1 and 2 carried by the connector itself to the appropriate holes on the cabinet socket using a small flathead screwdriver, see Figure 3-18.
  • Page 43 Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch PGND). This chassis ground must be securely connected to the earth ground so that the faradism and leakage electricity can be safely released to the ground, enhancing the EMS capability of the switch. Ground your switch as follows: When a grounding strip is available at the installation site, attach one end of the yellow/green ground wire of the switch to the grounding screw on the grounding...
  • Page 44 Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch For an AC-powered switch, if none of the above two conditions is available, ground it through the PE wire of the AC power supply. In this case, make sure this PE wire is well connected to the ground at the power distribution room or AC transformer side.
  • Page 45: Connecting The Switch To A Console Terminal

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch 3.5 Connecting the Switch to a Console Terminal 3.5.1 Console Cable Console cable is an 8-core shielded cable. At one end of the cable is a crimped RJ-45 connector for the connection to the console port of the switch;...
  • Page 46: Installing/Removing The Stack Cable

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch Caution: Read the mark for the port to be connected carefully to make sure it is the right port. Note: The serial ports on PCs do not support hot swapping. Therefore, do not insert or remove a serial interface cable from a PC that is connected to a switch with power.
  • Page 47: Removing The Stack Cable

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch 3.6.3 Removing the Stack Cable Step 1: Wear an ESD wrist strip and make sure it is well grounded. Step 2: Use a flat-blade screwdriver or power screwdriver to unscrew the captive screws at both sides.
  • Page 48: Verifying Installation

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 3 Installing the Switch II. Removing Step 1: Wear an ESD wrist strip which is well grounded. Step 2: Use the Phillips screwdriver to unscrew the captive screws at both sides of the module.
  • Page 49: Chapter 4 Starting Up The Switch At The Initial Boot

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Chapter 4 Starting up the Switch at the Initial Boot 4.1 Setting up a Configuration Environment Set up a configuration environment as shown in Figure 4-1. Connect a terminal, a PC in this scenario to the console port on the switch with a console cable.
  • Page 50 Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Figure 4-2 Setting up a new connection Step 2: Enter the name of the new connection in the Name field and click <OK>. The dialog box, as shown in Figure 4-3 displays.
  • Page 51 Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Stopbit = 1 Flow control = none Figure 4-4 Setting communications parameters Step 6: Click <OK>. The HyperTerminal dialogue box appears. Figure 4-5 HyperTerminal window Step 7: Select Properties.
  • Page 52: Booting The Switch

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Step 10: Click <OK>. Figure 4-6 Settings tab 4.4 Booting the Switch 4.4.1 Verifying Installation before Power-up Before powering up the switch, check that: Both the power cord and the grounding wire are correctly connected.
  • Page 53 Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot Creation date : Apr 10 2007, 12:51:33 CPU type : BCM1122 CPU Clock Speed : 400MHz BUS Clock Speed : 33MHz Memory Size : 128MB Mac Address : 000fe2005600...
  • Page 54 Installation Manual H3C S5600 Series Ethernet Switches Chapter 4 Starting up the Switch at the Initial Boot You can configure the switch now. Note: A wide range of command views are available for H3C Series Switches. For more information on configuration commands and command line interfaces, refer to H3C S5600 Series Ethernet Switches Operation Manual and H3C S5600 Series Ethernet Switches Command Manual.
  • Page 55: Chapter 5 Loading Boot Rom And Host Software

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Chapter 5 Loading Boot ROM and Host Software Switch software loading through serial ports in the past is time consuming and cannot be operated remotely. To address these problems, TFTP and FTP are used to allow software and file downloading through Ethernet ports.
  • Page 56 Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software H3C S5600 BOOTROM, Version 409 *********************************************************** Copyright(c) 2004-2007 Hangzhou H3C Technologies Co., Ltd. Creation date : Apr 10 2007, 12:51:33 CPU type : BCM1122 CPU Clock Speed : 400MHz BUS Clock Speed : 33MHz Memory Size : 128MB...
  • Page 57: Loading Software From Console Port Using Xmodem

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software 5.2.2 Loading Software from Console Port Using XModem I. Introduction to XModem XModem is a file transfer protocol widely used for its simplicity and good performance. XModem transfers files through the console port, supporting data packets of 128 bytes and 1 KB.
  • Page 58 Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Step 4: To download files, enter <Y>; to return to the loading menu, enter <N>. Press <Y> for example, the system displays: Download baudrate is 115200 bps. Please change the terminal's baudrate to 115200 bps and select XMODEM protocol.
  • Page 59 Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Figure 5-2 Console Port Configuration dialog box Step 6: Click <Disconnect> to disconnect the HyperTerminal from the switch and then click <Call> to re-establish the connection, thus validating the baud rate setting. Figure 5-3 <Disconnect>...
  • Page 60 Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Now please start transfer file with XMODEM protocol. If you want to exit, Press <Ctrl+X>. Loading ...CCCCCCCCCC Step 8: Select [Transfer/Send File] in the HyperTerminal’s window, and in the popup dialog box similar to the following figure click <Browse>, select the software you need to download, and set the protocol to XModem.
  • Page 61: Loading Software From An Ethernet Port Using Tftp

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Note: You do not need to reset the HyperTerminal’s baud rate and can skip the last step if you have chosen 9600 bps. In this case, the system does not display the above prompt message but “BootROM is updating now........done!”...
  • Page 62 Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Caution: TFTP Server program is not provided with the H3C Series Switches. Step 3: Run terminal emulation program on the PC that is connected to the console port. Start the switch, access the Boot Menu, and then enter the download protocol menu.
  • Page 63: Loading Software From An Ethernet Port Using Ftp

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software 2. Set FTP protocol parameter 3. Set XMODEM protocol parameter 0. Return to boot menu Enter your choice(0-3):3 Select <1>. The subsequent steps are the same as those for loading Boot ROM, except for the program to be downloaded in prompt messages.
  • Page 64: Loading Software Remotely

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Step 5: Input the FTP parameter values and press <Enter>. The system displays: Are you sure to update your bootrom?Yes or No(Y/N) Step 6: Press <Y> to start file downloading and <N> to return to the program downloading menu.
  • Page 65: Loading Software Remotely Using Tftp

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 5 Loading Boot ROM and Host Software Password: 230 Logged in successfully [ftp] get SWITCH.bin SWITCH.bin [ftp] get SWITCH.btm SWITCH.btm [ftp] bye Step 2: Load Boot ROM. <H3C> boot bootrom SWITCH.btm please wait ... Bootrom is updated! Step 3: Load the host software.
  • Page 66: Chapter 6 Maintenance And Troubleshooting

    Installation Manual H3C S5600 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting Chapter 6 Maintenance and Troubleshooting 6.1 Dealing with Loading Failures If software loading fails, the system operates with the original version. To address the failure cause, take these steps: Check that the physical ports are correctly and securely connected.
  • Page 67 Installation Manual H3C S5600 Series Ethernet Switches Chapter 6 Maintenance and Troubleshooting I. No information on the terminal Take these steps to address the problem: Check that: The power system is operating normally. The console cable is connected correctly. Check that the console cable is in good condition and the terminal (HyperTerminal for example) parameter settings are correct.
  • Page 68 Installation Manual H3C S5600 Series Ethernet Switches Table of Contents Table of Contents Appendix A Lightning Protection of the Switch.................A-1 A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection)..A-1 A.2 Installation of Lightning Arrester for Network Port.............A-2...
  • Page 69: Appendix A Lightning Protection Of The Switch

    Installation Manual H3C S5600 Series Ethernet Switches Appendix A Lightning Protection of the Switch Appendix A Lightning Protection of the Switch A.1 Installation of Lightning Arrester for AC Power (Socket Strip with Lightning Protection) Caution: Lightning arrester will not be shipped with the switch. You should purchase it by yourself if needed.
  • Page 70 Installation Manual H3C S5600 Series Ethernet Switches Appendix A Lightning Protection of the Switch Caution: Make sure that the arrester is well grounded before using the lightning arrester for power. After inserting AC power cord plug of switch into the socket of lightning arrester, if the green LED is on and the red LED does not alarm, it means that the lightning arrester of power is running and the function of lightning protection has taken effect.
  • Page 71 Installation Manual H3C S5600 Series Ethernet Switches Appendix A Lightning Protection of the Switch Multimeter Tilted wire cutter II. Installation procedure Step 1: Tear the protection paper at one side of the double faced adhesive tape apart from the tape, and stick the tape on the surface of the arrester. Tear the protection paper at another side apart from the tape, and stick the arrester onto the chassis of the switch.
  • Page 72 Installation Manual H3C S5600 Series Ethernet Switches Appendix A Lightning Protection of the Switch III. Installation precautions Fully consider the following items in the installation process, otherwise, the performance of the lightning arrester for network port will be affected: Lightning arrester for network port is installed in reverse direction. In practice, the “IN”...

Table of Contents