Hwping Configuration; Configuration On A Hwping Server - 3Com WX3000 Series Operation Manual

Unified switches switching engine
Table of Contents

Advertisement

Test parameter
File name for FTP operation
(filename)
Number of jitter test packets to be sent
per probe (jitter-packetnum)
Interval to send jitter test packets
(jitter-interval)
Trap

HWPing Configuration

The TCP/UDP/jitter tests need the cooperation of HWPing client and HWPing Server, Other types of
tests need to configure HWPing client and corresponding different servers.

Configuration on a HWPing Server

You can enable both the HWPing client and HWPing server functions on a device, that is, the device
can serve as a HWPing client and server simultaneously.
HWPing server configuration tasks
Complete the following tasks to configure the HWPing server:
HWPing
server
configuration
Task
Enable the HWPing server
function
Configure a listening
service on the HWPing
server
Description
Name of a file to be transferred between HWPing client
and FTP server
Jitter test is used to collect statistics about delay jitter in
UDP packet transmission
In a jitter probe, the HWPing client sends a series of
packets to the HWPing server at regular intervals (you
can set the interval). Once receiving such a packet, the
HWPing server marks it with a timestamp, and then
sends it back to the HWPing client. Upon receiving a
packet returned, the HWPing client computes the delay
jitter time. The HWPing client collects delay jitter
statistics on all the packets returned in the test. So, the
more packets a jitter probe sends, the more accurate
the jitter statistics is, but the longer time the jitter test
costs.
Each jitter probe will send multiple UDP test packets at
regular intervals (you can set the interval). The smaller the
interval is, the faster the test is. But a too small interval
may somewhat impact your network.
A HWPing test will generate a Trap message no matter
whether the test successes or not. You can use the
Trap device to enable or disable the output of trap
messages.
You can set the number of consecutive failed HWPing
tests before Trap output. You can also set the number
of consecutive failed HWPing probes before Trap
output.
The HWPing server function is needed only for jitter,
TCP, and UDP tests.
You can configure multiple TCP/UDP listening
services on one HWPing server, with each listening
service corresponding to a specific destination IP
address and port number.
1-4
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wx3024Wx3010Wx3008

Table of Contents