Figure 1-1 HWPing illustration
Switch A
HWPing Client

Test Types Supported by HWPing

Table 1-1 Test types supported by HWPing
Supported test types
ICMP test
DHCP test
FTP test
HTTP test
DNS test
SNMP test
Jitter test
Tcppublic test
TCP test
Tcpprivate test
Udppublic test
UDP test
Udpprivate test

HWPing Test Parameters

You need to configure corresponding test parameters for each type of HWPing test. HWPing test
parameters can be configured on HWPing client only. For the configurations on HWPing client, refer to
section.
Table 1-2 HWPing test parameters
Test parameter
Destination address (destination-ip)
Destination port (destination-port)
IP network
HWPing Server
For these types of tests, you need to configure HWPing client
and corresponding servers.
These types of tests need the cooperation of HWPing client
and HWPing Server.
Do not perform TCP or UDP test on port 1 to 1023
(well-known ports). Otherwise your HWPing test may fail or
cause the service corresponding to the well-known port (1 to
1023) being unavailable.
For TCP/UDP/jitter test, you must specify a destination IP
address, and the destination address must be the IP
address of a TCP/UDP/UDP listening service configured
on the HWPing server.
For tcpprivate/udpprivate/jitter test, you must specify a
destination port number, and the destination port number
must be the port number of a TCP or UDP listening service
configured on the HWPing server.